Instruction manual ADM 41
gis
7 The control panel
7.1 Introduction
Topics covered in this chapter, in sequence:
Control panel;
On/off switch
;
Control thermostat;
Control thermostat
.
7.2 Control panel
This figure shows the control panel.
The control panel
The control panel comprises:
an ON/OFF switch (with positions I/0);
a control thermostat with rotary knob.
7.3 Control thermostat
Use the rotary knob of the control thermostat to set the
desired water temperature between ± 40 °C and
± 70 °C. The range is continuous and is labeled 1
through 4. The table shows the temperatures
coresponding to the numbers on the knob.
Temperature settings
7.4 On/off switch
You use the on/off switch to set the appliance in:
ON mode (position I);
OFF mode (position 0).
The appliance remains live, even when in the OFF
mode. This ensures that the frost protection remains
activated.
Note
To isolate the appliance electrically, you must use
the isolator between the appliance and the mains
power supply.
7.5 Flue gas thermostat reset button
A malfunction in the flue gas discharge, e.g. a
blockage in the chimney, can lead to the flue gas
thermostat locking out. This state is evident when the
push button on the flue gas thermostat has been
activated (refer to the figure). Once the cause has
been removed, and the sensor has cooled down
sufficiently, press this push button to reset (if the
sensor is not sufficiently cooled down, the flue gas
thermostat will immediately lock out again). The
appliance will then automatically start up again, if
there is demand. If this is not the case, please consult
the error condition summary (11 "
Troubleshooting").
Note
The draught diverter may be hot.
Flue gas thermostat reset button
Position Temperature
40°C
50°C
60°C
70°C
IMD-0507 R0
12
IMD-0140 R2
41


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.O. Smith ADM 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.O. Smith ADM 50 in the language / languages: English as an attachment in your email.

The manual is 1,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.O. Smith ADM 50

A.O. Smith ADM 50 Usermanual and installation guide - Dutch - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info