A.caminetti wood-burning stoves have been tested and approved by testing institutes in accordance with
applicable law. Prior to final approval, the stoves are subjected to various fire technical tests. Your wood-
burning stove has been tested with a top outlet. Birchwood with 12 - 20% humidity was used during the
testing.
You should ensure that your stove is installed in accordance with applicable codes, regulations and safety
distances for combustible material. All A.caminetti dealers will be happy to tell you about the requirements
applying to your specific stove and give you further instructions on its correct installation. Furthermore,
your dealer / chimney sweep may tell you exactly which type of chimney you need to choose.
You should ensure that sufficient combustion air is delivered to the stove, also with the simultaneous use
of other heating or exhaustion devices. The insulation of contemporary homes is often so good that fresh
air valves are necessary to supply fresh air from outside. If you home is fitted with fresh air grates, any
blocking of these must be prevented.
Furthermore, you should check if the vermiculite plating is fitted correctly in the fire chamber. Please refer
to the illustration in this manual for positioning instructions.
To prevent the risk of fire, the heater must be installed in compliance with the rules and
regulations of good building practice, and with the technical guidelines provided in this
Installation and Operation Manual. The design of the chimney system must be by a qualified
specialist. Prior to commissioning, a recorded technical acceptance must be conducted and the
chimney sweep and fire-specialist assessments attached.
a)Prior to the heater’s installation, the chimney flue must be assessed by an expert and
accepted for its technical specifications, as well as the technical functionality of leak tightness
and flow capacity.
b)The installation and startup of the heater must be carried out by an installation-specialist
company with satisfactory qualifications and experience.
c)The heater must be placed as close to the chimney flue as possible. The room it will be
installed in must have a functional ventilation system and the required amount of air for correct
heater operation.
d) Before you start using the heater, remove the stickers from the glass.
e)The heater’s technical specifications apply to the fuel defined herein.
f) ) The chimney flues must be inspected in the due time (min. twice a year).
g) Pursuant to the applicable law, a stove may not be the only source of heat, but a
supplementary one to the existing heating system only. The purpose of such a regulation is the
necessity to provide heating for buildings during a prolonged absence of residents.
The heater’s installation must be performed with adherence to the provisions in force within this
standard scope, construction-law requirements and fire-safety standards in force in this regard.
The particular provisions on design safety, fire safety and safety of use are laid down in the
construction regulations and codes in force in the respective countries.
INSTALLATION
NOTE BEFORE INSTALLATION!!!
GENERAL REMARKS
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.Caminetti PANORAMA series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.Caminetti PANORAMA series in the language / languages: English as an attachment in your email.

The manual is 2.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of A.Caminetti PANORAMA series

A.Caminetti PANORAMA series User Manual - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info