7. If you do not want to add more fuel and the dose has burnt out, set the regulation of air to
the left to the minimum (Fig. 9). This will prevent burning air getting into the chamber and will
prolong the heat phase. The coal will remain hot in the chamber longer and the heat will not
escape through the chimney.
Notifcation: During active burning (visible fre), never close the air supply and do not
smoother the fre! Air fowing into the burning chamber cools the ceramic glass. If closing
the supply of air, it can be overheated and irreversible changes can occur in the crystalline
structure of the glass. During burning with an insuffcient air supply, an excessive amount of
harmful carbon monoxide - CO will originate. In the case of opening the air supply too fast,
there may be a rapid reaction of the collected gases with the oxygen.
10
Note!! In all the models the opening of air supply is when it is marked
number 1,the closing of air supply is when it is marked number 0.
4.2. OPERATION IN THE TRANSIENT PERIOD
For the correct function of the fireplace insert, a sufficient draught in the chimney is
required, which depends on the outdoor temperature. In winter when the outdoor
temperature is low, the chimney has the highest draught level. A problem with a sufficient
draught may occur in the transient period (before and after winter). A higher outdoor
temperature worsens the burning and increases the volume of the smoke. These undesirable
phenomena can be prevented as follows:
- When starting, increase the first dose of the fuel by 30 %, to quickly achieve the requested
draught in the chimney.
- Do not cut the wood into small pieces; this will result in heating the chimney too fast and
stabilize the draught.
- Leave the lever for the air supply in maximum position.
- Only add well dried wood.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for A.Caminetti Flat at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of A.Caminetti Flat in the language / languages: English as an attachment in your email.

The manual is 16.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info