2. INSTALLATION
2.1 POSITIONINGTHEAIRCONDITIONER(P3)
Tomaintainthebestperformancefromyourair
conditioner,preventbreakdownsorhazards,
youmustpositionitcorrectly.Pleasefollowthe
guidelinesandinstructionbelowinfull,as
failuretodosocouldcausepotential
installationproblems.
Theairconditionermustbeinstalledonan
exteriorwallthathasaccesstotheoutsidewith
aminimumofametersclearancetothe
outside.
Theairconditionermustbefittedleavingroom
allaroundasillustratedinthepapertemplate.
Thewallonwhichtheairconditioneris
installedmustbesturdyandabletowithstand
theweightoftheairconditioner.
Afterdeterminingthebestplaceforinstallation
asdescribedabove,pleasechecktoensurethat
thewallcanbedrilledinthechosenarea
withoutinterferingwithotherstructuresor
installation(beams,piers,pipes,wires,etc.).
Pleasealsoensurethattherearenoobstacles
ontheoutsideofthewall,whichmayobstruct
aircirculationthroughthedrilledholes,for
example:plantsandtheirleaves,slatsor
paneling,drainpipes,overflowsandgratings,
etc.Anyobstructioncouldinterferewiththe
correctperformanceoftheconditioner.
2.2 PAPERTEMPLATE(P4)
Fastenthetemplatetothewalloncethe
followingguidelineshavebeenthoroughly
checked.
Donotdrillanyholesuntilyouarecompletely
confidentthattherearenoobstaclesinthe
areayouwishtodrillandthereareno
obstructions,whichcouldbehiddenbythe
constructionofthewall,forexample:Electrical
wiring,water&gaspipesorsupportinglintelsor
beams.
Ensurethataspiritlevelisused,astheair
conditionermustbelevel.
Followtheinstallationinstructioninfull.
2.3 DRILLINGTHEWALL(P5)
Pleasenote:Ifyouaredrillingtheholeabove
groundfloorlevel,pleaseensurethatanarea
hasbeensecuredandwhiletheholesare
drilledtheoutsideareaissupervised,until
drillinghasbeencompleted.
INTAKEANDOUTLETHOLES:
Thisoperationshouldbecarriedoutusingthe
propertools(diamondtiporcoreborersdrills
withhightwistingtorqueandadjustable
rotationspeed).
Fastenthetemplatetothewalltakingcareto
checkthedistancefromthefloororceilingand
keepithorizontalbyusingaspiritlevel.
Useapilotdrilltomarkthecentreofeachcore
holetobedrilled.
Useacoreboringheadhavingadiameterof
162mmtodrillthetwoholesforintakeand
outlettheair.
Itisrecommendedthattheholesmust
haveaslightlydownwardinclinationof3
5degreetopreventanybackflowof
waterfromthepipes.
DRAINAGEHOLE(P13)
Thisairconditionerhasadoubledrainage
systemtodrainthecondensatemoisture
automatically.Beforeinstalltheairconditioner,
choosewhichoneisthesuitablesystemfor
yourinstallation.Pleasereadcarefullythe
followinginstructions.
System“A”:
Drillaholethroughthewallmeasuring30mm
diameterIthepositionshowninthepaper
template.Drainageoccursbygravity.Forthis
reason,itisessentialforthedrainlinetohave
aminimumdownwardinclinationatleast3
degreesthroughoutitslength.Connectthe
drainpipe(fromrubberterminal)totheair
conditioner(backside)afterunpluggedthe
blackrubbercup(seepic13).Withthissolution
youcandrainthecondensatemoisturetoa
suitableplacetodonotcauseanyproblemsto
ourneighbours.
3
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zymbo inVISE water SX-25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zymbo inVISE water SX-25 in the language / languages: English, French, Italian as an attachment in your email.

The manual is 4.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info