666302
10
Zoom out
Zoom in
Previous page
1/28
Next page
10
ZOOM RFX-2000
Using the MIDI Control Function
Using the MIDI Control Function
Setting the MIDI Channel
Selecting Patches Via MIDI
Storing Program Change Numbers in the Learn Table
The RFX-2000 can accept commands via a MIDI link for patch switching, parameter control, and transfer of memory contents to
an external MIDI device. This section describes the general steps for using MIDI based functions.
1. In play mode, press the MIDI key once.
The indication "CH" and the currently selected MIDI
channel are shown alternately on the display.
2. Use the VALUE UP/DOWN keys to select a
MIDI channel between 1 and 16. When the
display shows "--", the MIDI send/receive
function is disabled.
3. Press the CANCEL key to return to the play
mode.
CANCEL
CANCEL key
MIDI
Press once
Shown
alternately
MIDI key
1. Connect the MIDI OUT connector of the
external MIDI device to the MIDI IN connector
on the RFX-2000.
The MIDI channel setting at the RFX-2000 must match
the MIDI send channel setting at the external device.
2. Send a program change message from the
external MIDI device to the RFX-2000.
In the factory default condition, the RFX-2000 patch
numbers correspond to the following program change
numbers.
When the patch is switched at the RFX-2000, a
corresponding program change message appears at the
MIDI OUT connector.
RFX-2000
patch number
Program
change number
01
02
99
0.0
0.0
0
1
98
99
127
1. In play mode, select the patch to which you
want to assign a program change number and
press the MIDI key two times.
The indication "PC" and the indication "--" are shown
alternately on the display.
2. Send a program change message from the
MIDI device connected to the MIDI IN
connector of the RFX-2000.
The display indication "--" changes to the received
program change number. This program change number is
now assigned to the currently selected patch.
3. When wishing to assign a separate program
change number to this patch, repeat step 2.
It is also possible to assign multiple program change
numbers to the same patch number.
4. When the setting is complete, press the
CANCEL key to return to the play mode.
If necessary, repeat steps 1 - 4 for other patch numbers
and program change numbers.
The program change numbers 100 - 127 are shown on
the display as "0.0" - "2.7".
The changed learn table information is retained also
when the unit is turned off. (For information on how to
return the learn table to the factory default setting, see
page 13.)
CANCEL
CANCEL key
MIDI
Press twice
Shown
alternately
MIDI key
To switch the patch of the RFX-2000, a program change message must be sent from a MIDI keyboard or sequencer or similar
device to the RFX-2000.
Sometimes it may be desirable to assign specific program change numbers to the patch numbers of the RFX-2000. (For example
to call up patch number 1 of the RFX-2000 when the tone associated with program change 100 of a synthesizer is selected.) In
such a case, you can use the so-called learn table in the memory of the RFX-2000 to change the program change number assigned
to the patch number.
Set the MIDI channel for communication with the RFX-2000 as follows.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zoom RFX2000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zoom RFX2000 in the language / languages: English as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info