629759
5
Zoom out
Zoom in
Previous page
1/37
Next page
ZOOM B2.1u
5
Operating the B2.1u on batteries
Turn the B2.1u over and open the cover
of the battery compartment on the bottom.
B2.1u
bottom view
Latch
Latch
Cover
Press the latch to release
it and then raise the cover.
1.
Insert four fresh IEC
R6 (size AA) batteries.
2.
Close the cover of
the battery compartment.
3.
Four IEC R6
(size AA) batteries
Insert batteries facing
in alternate directions.
Use four IEC R6 (size AA) batteries.
When the batteries are getting low, the
indication "bt" appears on the display.
Push the cover in until the
latch audibly snaps into
place.
LO EQZNR/MIXDRIVE/SYNTHCOMP/LIMIT WAH/EFX MOD/SFXHI EQ DELAY REVERB
IN OUT
Terms Used in This Manual
This section explains some important terms that are used throughout the B2.1u documentation.
Effect module
As shown in the illustration above, the B2.1u can be
thought of as a combination of several single effects.
Each of these effects is referred to as an effect module.
In addition to modules comprising compressor and
limiter effects (COMP/LIMIT), amp simulator/synth
bass effects (DRIVE/SYNTH), and modulation/special
effects (MOD/SFX), the B2.1u also provides a module
for ZNR (ZOOM Noise Reduction). Various
parameters such as effect intensity can be adjusted for
each module individually, and modules can be
switched on and off as desired.
Effect type
Within some effect modules, there are several
different effects which are referred to as effect types.
For example, the modulation/SFX effect module
(MOD/SFX) comprises chorus, flanger, pitch shifter,
delay, and other effect types. Only one of these can
be selected at a time.
Effect parameter
All effect modules have various parameters that can
be adjusted. These are called effect parameters.
In the B2.1u, effect parameters are adjusted with the
parameter knobs 1 – 3. Similar to the knobs on a
compact effect, these change aspects such as tonal
character and effect intensity. Which parameter is
assigned to each knob depends on the currently
selected effect module and effect type.
Patch
In the B2.1u, effect module combinations are stored
and called up in units referred to as patches. A patch
comprises information about the on/off status of each
effect module, about the effect type used in each
module, and about effect parameter settings. The
internal memory of the B2.1u holds up to 80 patches
(including 40 patches which allow read/write).
Bank and area
A group of ten patches is called a bank. The memory
of the B2.1u comprises a total of eight banks,
labelled A to d and 0 to 3. Banks A – d form the user
area which allows read/write. Banks 0 to 3 are the
preset area containing read-only patches.
The patches within each bank are numbered 0
through 9. To specify a patch of the B2.1u, you use
the format "A1" (patch number 1 from bank A), "06"
(patch number 6 from bank 0), etc.
Play mode/edit mode
The internal status of the B2.1u is referred to as the
operation mode. The two major modes are "play
mode" in which you can select patches and use them
for playing your instrument, and "edit mode" in
which you can modify the effects. The module
selector serves for switching between the play mode
and edit mode.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zoom B2.1u at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zoom B2.1u in the language / languages: English as an attachment in your email.

The manual is 1,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info