460315
8
Zoom out
Zoom in
Previous page
1/16
Next page
F ADJUSTING THE WICK HEIGHT
After a period of time the combustion may no longer be high enough (Section D). In
that case you can adjust the wick height to improve the flame. To do this, the heater
must have been switched off. Follow the procedure below:
P
ush the OFF-button
³ (
Fig. L).
Pull the knurled wick adjustment knob
· off the heater, so the wick height
lock
ƺ will be visible.
Take the plastic collar between your thumb and index finger and pull it out.
Turn the collar up one step, to either position 2 or 3 (Fig. R). Carefully push
the collar back, so the pin engages in the recess.
Carefully reinstall the knurled wick adjustment knob. This can be done in one
way only - check the rear of the cap for the correct position.
If adjustment of the wick height does not have the required effect, let the
heater burn until all fuel has been used up (Section H).
If the flame height is still too low and the wick is set on position 3, then contact your
dealer,
or replace the wick, refer to section M.
If the flame gets too high after adjus-
ting (Fig P), the wick height lock should be placed one position lower again.
Otherwise smoke or soot may be caused.
G MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact
your Zibro dealer.
THE HEATER DOES NOT IGNITE
̈ The batteries are not positioned correctly in the holder. Check (Fig. F).
̈ There is not enough power left in the batteries for the ignition. Replace (Fig. F).
̈ You have run out of fuel from the tank or the wick has been replaced.
After having r
efilled and r
eplaced the removable tank, wait for 30 minutes
before igniting the heater.
̈ Y
ou are pushing the Ignition button
» with too much for
ce.
Push it down less forcefully (Section C).
̈ The ignition coil ¸ is defective.
Contact your dealer.
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
̈ The combustion chamber ¿ has not been positioned correctly.
Use the handle ´ to put it level, until you can easily slide it slightly to the left
and to the right and the chamber is level.
̈ The flame height has not been adjusted properly.
See Fig. P and the directions in Section D.
̈ Y
ou are using fuel which is past its ‘use by’ date.
Star
t ever
y heating season with fresh fuel.
̈ You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (Section ’What you need to know in advance’).
̈ Dust has gather
ed in the lower par
t of the heater
.
Contact your dealer.
̈ The wick heigt is not cor
r
ect.
See Section F.
THE HEATER SLOWLY EXTINGUISHES
̈ The removable tank is empty.
4
3
2
1
4
68
broken ignition coil
R
F
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zibro Kamin R 421 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zibro Kamin R 421 E in the language / languages: English as an attachment in your email.

The manual is 0,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Zibro Kamin R 421 E

Zibro Kamin R 421 E User Manual - German - 16 pages

Zibro Kamin R 421 E User Manual - Dutch - 16 pages

Zibro Kamin R 421 E User Manual - Danish - 16 pages

Zibro Kamin R 421 E User Manual - French - 18 pages

Zibro Kamin R 421 E User Manual - Italian - 16 pages

Zibro Kamin R 421 E User Manual - Polish - 16 pages

Zibro Kamin R 421 E User Manual - Swedish - 16 pages

Zibro Kamin R 421 E User Manual - Spanish - 16 pages

Zibro Kamin R 421 E User Manual - Norwegian - 16 pages

Zibro Kamin R 421 E User Manual - Finnish - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info