I
f the flame height is still too low and the wick is set on position 3, then contact your
dealer,
or replace the wick, refer to section M.
If the flame gets too high after adjus-
ting (Fig Q), the wick height lock should be placed one position lower again.
Otherwise smoke or soot may be caused.
G MALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below, please contact
your dealer.
THE HEATER DOES NOT IGNITE
̈ The batteries are not positioned correctly in the holder. Check (Fig. N).
̈ There is not enough power left in the batteries for the ignition. Replace (Fig. N).
̈ You have run out of fuel from the tank or the wick has been replaced.
After having refilled and replaced the removable tank, wait for 30 minutes
before igniting the heater.
̈ You are pushing the ignition button » with too much force.
Push it in less forcefully (Section C).
̈ The ignition coil ¹ is defective. Contact your dealer.
IRREGULAR FLAME AND/OR SOOT AND/OR SMELLS
̈ The combustion chamber ¿ has not been positioned correctly.
Use the handle ´ to put it level, until you can easily slide it slightly to the left
and to the right and the chamber is level.
̈ You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
̈ You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
̈ Dust has gathered in the lower part of the heater. Contact your dealer.
̈ Wick position wrong. See Section F.
THE HEATER SLOWLY EXTINGUISHES
̈ The removable tank is empty. See Section B.
̈ The fuel filter is contaminated by moist. Dry the fuel filter (Section H).
̈ The lower reservoir is contaminated by moist. Contact your dealer.
̈ The wick has hardened on the upper side.
Burn the heater until all fuel is used (Section H). Use the right fuel.
̈ You are using fuel which is past its ‘use by’ date.
Start every heating season with fresh fuel.
THE HEATER REMAINS BURNING LOW
̈ Wick position too low.
Reinstall the wick height lock (Section F).
̈ Before you refilled the tank, the heater had burnt up almost all the fuel.
After having refilled and replaced the removable tank, wait for 30 minutes
befor
e igniting the heater.
̈ You are using the incorrect type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
̈ The r
oom is insufficiently ventilated.
Leave a window or a door wide open for a while.
THE HEATER IS BURNING TOO HIGH
̈ You are using an incorrect, too volatile type of fuel.
Refer to THE RIGHT FUEL (See Section ’What you need to know in advance’).
̈ W
ick position too high.
Reinstall the wick height lock (Section F).
4
44
R 19 C
N
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zibro Kamin R 19C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zibro Kamin R 19C in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info