SIMPLY SYSTEM
TM
See Chapter 9 - Maintenance
4.2 SAFETY FEATURES
4.2.1. Mechanical safety features:
• The safety pressure valve exit is placed on the bottom of the machine.
so that steam, in case of overpressure, comes out underneath the device
with no harm to persons. The working pressure in the boiler is 4.5 Bar and
the safety valve must open within a range of maximum +2 Bar. The valve
must allow for more steam to exit from the valve than the boiler can create
so that pressure decreases.
• 2 INCOLOY 800 heat coils, extremely resistant against high temperatures
and against limestone deposits.
• Intake and outtake air for the vacuum motor are kept in separate directions
in order to keep the motor cooled.
4.2.2. Electric safety features:
• The boiler has a pressure sensor which guarantees that the pressure is
always around 4.5 Bar.
• It has a multi pin construction and by just inserting the plug, which has a
special sequence, the electricity will pass on to the commands
on to the hose, to the iron or any other electric accessory.
• If the sequence is correct, a resistor in the commands responds within a
very small tolerance range that our accessory is connected to; no foreign
accessory or object will be recognized.
• If these criteria are met, approximately 7 seconds pass (delay) prior to
freeing the electric circuit.
4.3 TECHNICAL DATA
Data plate characteristics
WARNING! Make sure the technical data on the data plate matches that of
your electricity mains.
Technical characteristics
• Voltage: 230 V +/- 6% 50 Hz
• Boiler power: 2100 W (1050+1050)W
• Motor vacuum power: 1200W higher technology gives same power as
a 1600 W motor but: quieter, lower vibrations, lower energy consumption,
higher reliability and higher air volume.
• Iron power: 850 W
• Steam pressure: (450 kPa) 4.5 bar
• Steam flow: 55 g/min
• Max. steam temperature in the boiler: 148°C
• Effective Air flow: 23.51 l/sec
• Vacuum pressure: 2290 mm H
2
O (~ 22.4 kPa)
• Time of heating: 2 min. approx after turning on the steam power, just a few
seconds with refill
• Boiler volume: 0.8 litres
• Boiler capacity: 0.4 litres
• Recovery tank volume: 1.2 litres
• Length of flexible tube: 2.0 m
• Working reach: 8 m
• Length of power lead: 5 m
• Working noise: 71 db(A)
Safety features:
• Service pressure switch: 2 ± 6 bar 0.3+/-0.15
• Safety thermostat: 170 °C
• Boiler safety valve: 6 bar +/- 0.5
• Low voltage handle commands:5 Volt
• Safety float
• Heat insulation in extension tubes
• Steam safety lock
Patented systems:
• Spray System
TM
• Slalom System
TM
• Simply System
TM
Product code: PWC-700B
• Weight: 9,7 kg
• Size: 336x332x479 mm
Safety heat insulation extension tubes:
separate tubes for 1 steam and 2 vacuuming,
3 outer tube protects from burning and
isolates the electric part 4.