1048 (170)
GASTYPE G20/25 G30/31
PRESSURE 20//20-25 30//29-37//30-50
COUNTRY
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
CATEGORY I2H//I2E+//I2E-I2ELL//I2L I3B/P//I3+//I3P
PRIMAIRY AIR 2xø8,5mm/1xø7mm 3xø16mm
PRE PRESSURE MBAR 20//20-25 30//29-37//30-50
BURNERPRESSURE HIGH MBAR 11/13,7 26,2//26,2-33,6//33,6
BURNERPRESSURE LOW MBAR 7,1/7,0 11,1//11,1-14,6//14,6
INJECTOR SIZE Ø MM 2x2,5 2x1,45
INJ. PILOTBURNER CODE 51 30
LOWSETTING SIZE MM 2,2 1,8
LOAD Hs KW 15,5/14,6 15,2//15,2-15//15
LOAD Hi KW 14/13,1 13,9//13,9-13,8//13,8
CONSUMPTION M³/h 1,48/1,62 0,43/0,55
NOM.OUTPUT kW 12/11 11,7/11
12.1 Gas technische gegevens
GASTYPE G20/25 G30/31
PRESSURE 20//20-25 30//29-37//30-50
COUNTRY
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
CATEGORY I2H//I2E+//I2E-I2ELL//I2L I3B/P//I3+//I3P
PRIMAIRY AIR 2xø6mm/1Xø4mm 3xø16mm
PRE PRESSURE MBAR 20//20-25 30//29-37//30-50
BURNERPRESSURE HIGH MBAR 14,4//16,5 15//14-18,5//15
BURNERPRESSURE LOW MBAR 2,5//3,2 10,7//10,7-13,2//10,7
INJECTOR SIZE Ø MM 2x2,0 2X1,4
INJ. PILOTBURNER CODE 51 30
LOWSETTING SIZE MM 1,8 1,3
LOAD Hs KW 12,4//10,8 10,15//10,15-9,8//9,8
LOAD Hi KW 11,1/9,7 9,3//9,3-9//8,2
CONSUMPTION M³/h 1,22//1,19 0,29//0,34-0,37//0,34
NOM.OUTPUT kW 9,3//8,1 7,6//7,6-7,35//7,35
1137 / 1138 (120/120 tunnel)
GASTYPE G20/25 G30/31
PRESSURE 20//20-25 30//29-37//30-50
COUNTRY
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
CATEGORY I2H//I2E+//I2E-I2ELL//I2L I3B/P//I3+//I3P
PRIMAIRY AIR 2xø6,5mm/2xø4,5mm 3xø16mm
PRE PRESSURE MBAR 20//20-25 30//29-37//30-50
BURNERPRESSURE HIGH MBAR 11//14 14//17-18//13,8
BURNERPRESSURE LOW MBAR 9//11,3 10,4//10,5-13//10,5
INJECTOR SIZE Ø MM 2x2,2mm 2x1,4mm
INJ. PILOTBURNER CODE 51 30
LOWSETTING SIZE MM 1,8 1,3
LOAD Hs KW 12,6//11 10,6//10,6-10,5//9,5
LOAD Hi KW 11,3/9,9 9,8//9,8-9,66//8,7
CONSUMPTION M³/h 1,2//1,25 0,3//0,3-0,35//0,35
NOM.OUTPUT kW 9,45//8,25 7,95//7,95-7,9//7,12
1139 / 1149 (140/140 tunnel)
GASTYPE G20/25 G30/31
PRESSURE 20//20-25 30//29-37//30-50
COUNTRY
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
NL/NO/DK/DE/ES/PT/IE/GB/BE/FR/AT/SI/
HU/PL/CY/MT/IT/CH/CZ/SK/SI
CATEGORY I2H//I2E+//I2E-I2ELL//I2L I3B/P//I3+//I3P
PRIMAIRY AIR 2xø7,5mm/2xø4mm 3xø16mm
PRE PRESSURE MBAR 20//20-25 30//29-37//30-50
BURNERPRESSURE HIGH MBAR 14,3//17,8 24,6//24,6-30,4//24,6
BURNERPRESSURE LOW MBAR 13,2//16,6 11,8//11,8//14,4
INJECTOR SIZE Ø MM 2x2,3mm 2x1,45
INJ. PILOTBURNER CODE 51 30
LOWSETTING SIZE MM 2,2 1,3
LOAD Hs KW 16,1//14,3 14,3//14,3-14,2//13,1
LOAD Hi KW 14,5/12,8 13,2//13,2-13//12
CONSUMPTION M³/h 1,53//1,58 0,41//0,41-0,53//0,49
NOM.OUTPUT kW 12/10,7 8,8//8,8//10,8
1135 / 1136 (100/100 tunnel)
Alle toestellen NoX Klasse 5
AT I2H, I3B/P BE I2E+ , I3+ DK I2H, I3B/P DE I2ELL, I3B/P FI I2H, I3B/P FR I2E+, I3+ GR I2H, I3B/P
GB I2H, I3+ IS I3B/P IE I2H, I3+ IT I2H, I3+ LU I2E, I3B/P NL I2L, I3B/P NO I3B/P
PT I2H, I3+ ES I2H, I3+ SE I2H, I3B/P CY I3B/P,I3+ EE I3B/P,I2H LT I3B/P,I2H LV I3B/P,I2H
MT I3B/P HU I3B/P,I2H PL I3B/P SI I3B/P,I2H SK I2H
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zen Fires 120 T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zen Fires 120 T in the language / languages: Dutch as an attachment in your email.

The manual is 3,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info