540054
34
Zoom out
Zoom in
Previous page
1/36
Next page
34 PG-001_v01
Wiring diagram:
Before installing make sure that the local distribution
conditions (the type of gas, its pressure) and the
appliance adjustment are compliant.
The conditions of gas adjustment of the appliance are
indicated on the nameplate.
The appliance is not connected to the fumes conduits.
It should be installed and connected according to
the binding installation regulations. The appropriate
requirements concerning ventilation should be taken into
consideration.
The exible gas connection shall be assembled such
way, that it is not in contact with the furniture parts in
move (i.e. drawer) and it shall be not located in the are
with not enough space.
The wiring supplying the power to the hob shall be
secured with properly selected safety device.
Upon installing the hob, the installer is obliged to check
the tightness of the gas tting.
REMARK: The installer is obliged to ll in the warranty
card, which is the basis for the warranty and guaranty.
Replacing the nozzles for the other
type of gas (Fig. B)
ATTENTION: The hob nozzles replacing can be
executed only by an authorised quali ed installer.
The gas hob is the nozzles are defaulted for 2E (G20) gas.
The other kinds of gas are:
BURNER GAS PRESSURE NOZZLE
MARKING
THERMAL
CAPACITY
LARGE (G20)
(G30)
(G30/31)
20 mbar
37 mbar
28-30/37 mbar
117 Y
79
88
750-3000 W
750-3000 W
750-3000 W
MEDIUM (G20)
(G30)
(G30/31)
20 mbar
37 mbar
28-30/37 mbar
98 Z
63
68
500-1750 W
500-1750 W
500-1750 W
SMALL 2(G20)
(G30)
(G30/31)
20 mbar
37 mbar
28-30/37 mbar
75 X
48
51
400-1000 W
400-1000 W
400-1000 W
1
Remove the cap and crown.
2
Unscrew the nozzle using a special spanner.
3
Replace the nozzle screwing the appropriate one
according to the table.
After the nozzles exchange adjust the burners (see
”FLAME ADJUSTMENT”.
Upon nozzles replacement glue an adequate label
indicating the gas type near the end of shaft connecting
the hob manifold.
Technical speci cation
The technical parameters of the hob are indicated at the
nameplate of the appliance.
The hob is equipped with a shaft with threaded end of G1/2”
diameter for connecting to gas supply tting. In case of
connection to LPG cylinder (propane –butane) the ending
of the exible hose
8 x 1mm is screwed on the threaded
shaft end.
The gas hob is the 1st class appliance equipped with a
connecting cord with protecting stand. It requires connection
to the socket equipped with an earth pin.
the appliance meets the requirements of the standards in
force.
The appliance is in conformance with the requirements of the
following directives:
Appliances burning gaseous fuels – 90/396/EEC,
93/68/EEC.
Low Voltage Devices (LVD) – 2006/95/EC.
Electromagnetic compatibility (EMC) – 2004/108/EC.
The product has been labelled with CE mark on the
nameplate.
The appliance outline (Fig. D)
1
Large burner Ø 100 mm 3,0 kW
2
Medium burner Ø 75 mm 1,75 kW
3
Small burner Ø 55 mm 1,0 kW
4
Burner control knobs with electric ignition candle
5
Burner grate
6
Burner cap
7
Burner crown
8
Burner body
9
Anti-gas ow security device
10
Ignition candle
Flame adjusting (Fig. C)
1
Switch on the burner and set the minimum ame .
2
Remove the ring knob from the spindle.
3
Adjust the ame turning the screw inside the spindle with
an appropriate screwdriver.
Check if the ame is not off in case of fast switching
from
maximum to minimum ame.
In case of 3B/P (G30) gas, the screw must be screwed
until it turns(clockwise).
yellow-green
brown
blue
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zelmer ZPG6014CP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zelmer ZPG6014CP in the language / languages: English, Polish as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info