Rewind the cord pressing cord rewind button. Hold the plug when rewinding, do not allow the cord to get entangled and the plug –
to bump the casing.
You can store the vacuum cleaner in both horizontal and vertical positions. The hose can remain tted, but please be careful not
to bend it too much.
Horizontal storage:
insert the handle located in back part of brush – nozzle into the handle socket at the backside of the vacuum cleaner near the –
supply cord inlet.
Vertical storage:
insert brush – nozzle on telescope pipe,–
insert the handle into the handle socket at the bottom of the vacuum cleaner next to front wheel. –
FULL DUST COMPARTMENT INDICATOR
Full bag indicator glowing (red colour), when the nozzle or brush is above the cleaned surface, informs us that it is necessary to
empty dust compartment.
Full bag indicator can activate also in case of blocked sucking hose or one of connected accessories. In such case, remove the
hose from front lid and clean the hose and connected accessories.
DUST COMPARTMENT – emptying, cleaning
The vacuum cleaner is equipped with a dust compartment, which is a removable part of the vacuum cleaner
When removing dust compartment switch off and unplug from mains supply outlet.
Remove the dust compartment from the vacuum cleaner. In order to do it:–
press the dust compartment button, simultaneously removing all this part of the vacuum cleaner,–
place the compartment ovr the dust bin.–
After pressing the compartment button, the bottom of the compartment shall open and the content shall fall –
into the dust bin.
After emptying the dust bin lock the bottom and insert the compartment into the vacuum cleaner.–
VACUUM CLEANER FILTERS
The vacuum cleaner is equipped with the lter system:
Inlet-air lter cone.
Motor protecting lter.
Outlet-air lter.
Inlet-air lter cone – cleaning
The lter is located inside the dust compartment. In order to exchange it:–
Empty the dust compartment (see the item. –DUST COMPARTMENT – emptying, cleaning).
Turn the inlet lter cone in direction of –„1” and remove it in your direction „2”.
Clean the cone, wash it, rinse it and dry thoroughly.–
In case of inlet cone damage replace it with a new one.
ATTENTION! Turn your atttention to the basket at the bottom of the cone ange. Do not loose it.
After inlet –air cone cleaning:
Insert the cone into the cone socjet, so that two protrusions –„A” located on the ange got under the locker
„B” in the compartment casing
Press the cone strong and turn it in direction of –„3”, until it runs, sou will hear characteristic clicking sound,
close (lock the bottom of the compartment).–
Insert all the unit into the vacuum cleaner chamber (see the item –DUST COMPARTMENT – emptying,
cleaning).
HEPA motor protecing lter – exchange
Svislé
uskladnění
horizontal
storage
vertical
storage
Remove the dust compartmentu (see the item –DUST COMPARTMENT – emptying, cleaning).
After pulling out the locker of the lter grade, remove HEPA iter.–
Rinse the lter and dry it thoroughly.–
In case of lter damage replace it with a new one.
Attention! HEPA motor protecting lter should be replaced with a new one twice a Lear and
etery time when it is damaged.
Lock the grate with the lter.–
OUTLET FILTER - EXCHANGE
Switch off the vacuum cleaner and unplug it from the mains supply outlet.–
Drag out the lter outlet and remove it upwards.–
Remove the grid with outlet lter from the lter socket.–
Remove the outlet lter from the grid hooks.–
Wash, rinse and dry carefully the outlet lter.
Insert a new one in case it is damaged, assembling carefully at the grid hooks.
Insert the assembled grid into the lter socket.–
Insert the lter protection and lock it.–
CLEANING AND MAINTENANCE
Remember to check if the vacuum cleaner is unplugged before cleaning and maintenance. Clean the casing and bag chamber with damp cloth (it can be
wet with wash – up liquid) dry or wipe up to get it dry. Do not use abrasive agents or dissolvent. Vacuum the nozzle-brush, small brush or special acces-
sories with a gap nozzle from time to time.
WHAT TO DO WHEN…?
The vacuum cleaner was switched off during operation by over-heating protection:
switch off the appliance, unplug it from the mains supply outlet and wait approximately 40 minutes before you switch it on again,–
remove the dust compartment, empty it and clean the cone of the inlet-air lter and HEPA outlet-air lter.–
Do not assemble dust compartment section until the vacuum cleaner cools down:
check and clean the accessories: sucking hose, pipes, nozzle and brushes,–
re-assemble the vacuum cleaner and start it up,–
if the over-heating protection repeats to often, or you can not switch on the vacuum cleaner after cooling, bring your vacuum cleaner to service desk.–
Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.
Product:
Forumrules
To achieve meaningful questions, we apply the following rules:
First, read the manual;
Check if your question has been asked previously;
Try to ask your question as clearly as possible;
Did you already try to solve the problem? Please mention this;
Is your problem solved by a visitor then let him/her know in this forum;
To give a response to a question or answer, do not use this form but click on the button 'reply to this question';
Your question will be posted here and emailed to our subscribers. Therefore, avoid filling in personal details.
Register
Register getting emails for Zelmer 01z010 at:
new questions and answers
new manuals
You will receive an email to register for one or both of the options.
Get your user manual by e-mail
Enter your email address to receive the manual of Zelmer 01z010 in the language / languages: English, Polish as an attachment in your email.
The manual is 1,26 mb in size.
You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.
The manual is sent by email. Check your email
If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.
The email address you have provided is not correct.
Please check the email address and correct it.
Your question is posted on this page
Would you like to receive an email when new answers and questions are posted? Please enter your email address.