Width of the back of
the appliance
559 mm
Depth of the appliance 569 mm
Built in depth of the
appliance
548 mm
Depth with open door 1022 mm
Ventilation opening
minimum size. Opening
placed on the bottom
rear side
560x20 mm
Mounting screws 4x25 mm
ELECTRICAL CONNECTION
WARNING! Risk of fire and electric
shock.
All electrical connections should be made by a
qualified electrician.
The appliance must be earthed.
Make sure that the parameters on the rating
plate are compatible with the electrical ratings
of the mains power supply.
Always use a correctly installed shockproof
socket.
Do not use multi-plug adapters and extension
cables.
Make sure not to cause damage to the mains
plug and to the mains cable. Should the mains
cable need to be replaced, this must be carried
out by our Authorised Service Centre.
Do not let mains cables touch or come near the
appliance door or the niche below the
appliance, especially when it operates or the
door is hot.
The shock protection of live and insulated parts
must be fastened in such a way that it cannot be
removed without tools.
Connect the mains plug to the mains socket
only at the end of the installation. Make sure that
there is access to the mains plug after the
installation.
If the mains socket is loose, do not connect the
mains plug.
Do not pull the mains cable to disconnect the
appliance. Always pull the mains plug.
Use only correct isolation devices: line
protecting cut-outs, fuses (screw type fuses
removed from the holder), earth leakage trips
and contactors.
The electrical installation must have an isolation
device which lets you disconnect the appliance
from the mains at all poles. The isolation device
must have a contact opening width of minimum
3 mm.
This appliance is supplied without a main plug
and a main cable.
Cable types applicable for installation or re-
placement for Europe:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate. You can also refer to the table:
Total power (W) Section of the cable
(mm²)
maximum 1380 3 x 0.75
maximum 2300 3 x 1
maximum 3680 3 x 1.5
The earth cord (green / yellow cable) must be 2 cm
longer than phase and neutral cables (blue and
brown cables).
USE
WARNING! Risk of injury, burns and
electric shock or explosion.
This appliance is for household (indoors) use
only.
Do not change the specification of this
appliance.
Make sure that the ventilation openings are not
blocked.
Do not let the appliance stay unattended during
operation.
Deactivate the appliance after each use.
Be careful when you open the appliance door
while the appliance is in operation. Hot air can
release.
Do not operate the appliance with wet hands or
when it has contact with water.
Do not apply pressure on the open door.
Do not use the appliance as a work surface or
as a storage surface.
Open the appliance door carefully. The use of
ingredients with alcohol can cause a mixture of
alcohol and air.
4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zanussi ZOHNA7K1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zanussi ZOHNA7K1 in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Zanussi ZOHNA7K1

Zanussi ZOHNA7K1 User Manual - French - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info