671332
13
Zoom out
Zoom in
Previous page
1/20
Next page
A B
C
D
E
A. Green and Yellow
B. 3 amp fuse
C. Brown
D. Cord clamp
E. Blue
The wires in the cord are coloured as follows:
Green and yellow - Earth
Blue - Neutral
Brown - Live
WARNING! A cut off plug inserted
into a 13 amp socket is a serious
shock hazard. Ensure that the cut off
plug is disposed of safely.
REPLACEMENT OF THE CONNECTION
CABLE
The replacement of electric cable must
be carried out exclusively by the
service force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
To replace the connection cable use
only H03V2V2-F T90 or equivalent
type. Make sure that the cable section
is applicable to the voltage load and
the working temperature. The yellow/
green earth wire (B) must be
approximately 2 cm longer than the
live and neutral wire (A).
A B
1. Connect the green and yellow (earth) wire to
the terminal which is marked with the letter 'E',
or the earth symbol , or coloured green and
yellow.
2. Connect the blue (neutral) wire to the terminal
which is marked with the letter 'N' or coloured
blue.
3. Connect the brown (live) wire to the terminal
which is marked with the letter 'L'. It must
always be connected to the network phase.
There must be no cut or stray strands of wire
present. The cord clamp must be correctly
attached to the outer sheath.
ASSEMBLY
1.
2.
13
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zanussi ZGG66424 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zanussi ZGG66424 in the language / languages: English as an attachment in your email.

The manual is 0,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Zanussi ZGG66424

Zanussi ZGG66424 User Manual - German, Dutch - 52 pages

Zanussi ZGG66424 User Manual - Dutch - 20 pages

Zanussi ZGG66424 User Manual - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info