15
The motor seems to run too much
Is the lid not closed completely? See underneath.
Is the room termperature hotter than normal?
Has a large amount of fresh food just been added to the freezer?
Is the lid opened often?
Is the temperature control set correctly for the surrounding conditions?
Is the lid seal damaged or deformed?
Is there enough air circulation space around the freezer?
Is the Super Freeze function activated accidentally?
Termperature is too warm
Has a large amount of food just been added to the freezer?
Is the lid opened often?
Is the temperature control set correctly for the surrounding conditions?
Too much ice has formed
Is the lid not closed completely? See underneath.
Is the water drainage plug correctly positioned?
The lid will not close completely
Is there excessive frost or a package preventing the lid from closing?
Are food packages blocking the lid?
Is the lid seal dirty or sticky?
Does the freezer wobble or seem unstable?
The lid is difficult to open
Is the lid seal dirty or sticky?
Is the valve blocked?
If you still need help, please contact your local Sercive Force Centre.
Service or repair
In cases of breakdown or faults, your freezer must be serviced by an authorized Electrolux Service Centre.
Important! Under no circumstances should you attempt to repair the appliance yourself.
Technical Data
Model BNI325 BNI425 BNI525
ZFC30JC ZFC40JC ZFC50JC
Volume (gross) Liter 304 404 500
Volume (net) Liter 300 400 495
Height without/with roller Cm 87,6 87,6 87,6
Width Cm 105 132,5 160
Depth Cm 66,5 66,5 66,5
Weight Kg 49 56 66
Energy consumption/24h kWh/24h 1,149 1,384 1,608
Freezing capacity kg/24h 17 19 20
Hold-over time Hours 28 32 32
Rated power Watt 110 110 140
Voltage Volts 230 230 230
Climatic class SN SN SN
Climatic classification Ambient temperature limits
SN from +10°C to +32°C
N from +16°C to +32°C
ST from +18°C to +38°C
T from +18°C to +43°C
This appliance complies with the following EC Directives:
73/23/EEC of 19. 02. 1973 Low-Voltage Directive
89/336/EEC of 03. 05. 1989 (including Amendment Directive 92/31/EEC - EMC
Directive)
EN