133240
3
Zoom out
Zoom in
Previous page
1/24
Next page
3
GB
2.2 - Wall cabinet fixing
a - Predrilled wall cabinet: fix the hood onto the wall cabinet base panel using the four screws 4.2
x 45 mm (supplied with the fixing kit).
It is not necessary to open the metal grille.
b - No predrilled wall cabinet:
b.1 - If the hood is provided with a paper fixing template, follow the instructions.
b.2 - If the hood is not provided with a paper fixing template, position the hood on the wall
cabinet base panel and pilot drill the 3.5 x 16 mm screws (not supplied with the fixing kit)
from the inside onto the wood.
2.3 - Wall mounting
a - Drill two Ø 8 mm holes on the wall using the paper template, insert two rawl plugs and two 4.2
x 44,4 mm screws leaving 5 mm untightened. Open the metal grille panel, hook the hood on and fully
tighten the screws.
b - If the hood is not provided with a paper fixing template, drill two Ø 8 mm holes (see draw.), insert
the plugs and screws, proceeding as directed under paragraph a.
c - For wall mounting using wallbrackets (optional), follow the instructions of the fixing template.
d - Pay attention to the safety regulation of point 1.6.
2.4 - Choice of operating mode
a - Evacuation mode
To check that the hood is set up for evacuation, open the grille panel and make sure that the conver-
sion lever or the change-over knob on the centrifugal unit is in the DUCTING position. The charcoal
filter is not required.
For ducting to the outside, the hood is supplied with a rear and top outlet. A flange spigot of 100 mm
diameter (120 mm in certain models) is usually fitted on the top outlet and a blanking plug on the rear
outlet. If you choose to duct the hood from the rear of the casing, you should invert the position of
the flange and of the blanking plug. Pay attention to the safety regulation 1.1.
b - Internal recirculation mode
To check that the hood is set up for recycling, open the grille panel and make sure that the conversion
lever or the change-over knob on the centrifugal unit is in the RECYCLING position.
The charcoal filter is to be fitted. To fit the charcoal filter, support the filter with one hand and turn
the thumb screw through the centre of the charcoal filter. If the filter is of the interlocking type, turn
the filter clockwise. The hood can remain connected to the outside.
2.5 - Electrical connection and working test
1 - The safety measures 1.2, 1.3, 1.4 and 1.5 of paragraph 1 are to be strictly observed.
2 - Once the electrical connection has been completed, check that the worktop illumination, motor
and speeds work properly.
3 - OPERATION
3.1- Controls are located on the right hand side of the front to operate worktop illumination and select the
most suitable working speed for your cooking. To increase the area of extraction, the glass visor
should be pulled open. The top speed should be used when frying or cooking foods with strong
odours, while a lower speed can be used for normal cooking.
To obtain the best performance from your hood, turn it on before you start cooking and leave it
running for a few minutes after your cooking is over to clear the air.
3.2-Pay attention to safety regulations 1.7 and 1.8.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Zanker kht 6111 x at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Zanker kht 6111 x in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info