540488
81
Zoom out
Zoom in
Previous page
1/84
Next page
EX-B01E 2
IM 1F5B2-01E
(2) Shroud
A component part which is so designed that the fastening of joint surfaces cannot be
loosened unless a special tool is used.
(3) Enclosure internal volume
This is indicated by:— the total internal volume of the flameproof enclosure minus
the volume of the internal components essential to equipment functions.
(4) Path length of joint surface
On a joint surface, the length of the shortest path through which flame flows from
the inside to outside of the flameproof enclosure. This definition cannot be applied to
threaded joints.
(5) Gaps between joint surfaces
The physical distance between two mating surfaces, or differences in diameters if the
mating surfaces are cylindrical.
Note: The permissible sizes of gaps between joint surfaces, the path length of a joint
surface and the number of joint threads are determined by such factors as the
enclosure’s internal volume, joint and mating surface construction, and the
explosion classification of the specified gases and vapours.
4. Installation of Flameproof Apparatus
(1) Installation Area
Flameproof apparatus may be installed, in accordance with applicable gases, in a
hazardous area in Zone 1 or 2, where the specified gases are present. Those appara-
tus shall not be installed in a hazardous area in Zone 0.
Note:Hazardous areas are classified in zones based upon the frequency of the appear-
ance and the duration of an explosive gas atmosphere as follows:
Zone 0: An area in which an explosive gas atmosphere is present continuously or is
present for long periods.
Zone 1: An area in which an explosive gas atmosphere is likely to occur in normal
operation.
Zone 2: An area in which an explosive gas atmosphere is not likely to occur in normal
operation and if it does occur it will exist for a short period only.
(2) Environmental Conditions
The standard environmental condition for the installation of flameproof apparatus is
limited to an ambient temperature range from -20 to +40C (for products certified
under Technical Criteria). However, some field-mounted instruments may be
certified at an ambient temperature up to +60C as indicated on the instrument
nameplates. If the flameproof apparatus are exposed to direct sunshine or radiant heat
from plant facilities, appropriate thermal protection measures shall be taken.
5. External Wiring for Flameproof Apparatus
Flameproof apparatus require cable wiring or flameproof metal conduits for their
electrical connections. For cable wiring, cable glands (cable entry devices for flameproof
type) to wiring connections shall be attached. For metal conduits, attach sealing fittings
as close to wiring connections as possible and completely seal the apparatus. All non-
live metal parts such as the enclosure shall be securely grounded. For details, see the
“USER’S GUIDELINES for Electrical Installations for Explosive Gas Atmospheres in
General Industry,” published in 1994.
81


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa UYFA21 Ultrasonic Vortex Flowmeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa UYFA21 Ultrasonic Vortex Flowmeter in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info