9-1
IM 1F5B2-01E
9. STANDARD SPECIFICATIONS
9. STANDARD SPECIFICATIONS
9.1 STANDARD SPECIFICATION
Fluid to be Measured:Liquid
Measuring condition: Sound speed 500 to 2000 m/s
Be sure there are no bubbles in the flow.
Avoid severe sticky and slurry fluid meterings.
Do not use this meter where pulsating flow/pulsating pressure
exist.
Measurable Flow Rates: Refer to item 6.1.
Accuracy: ± 1.0% of reading
± 0.5% of reading is also available as an option.
(refer to item 6.1)
Note: The above shows the accuracy of pulse output. For analog
output, add up ± 0.1% of full scale to the above values.
Repeatability: ± 0.2% of reading
Process Temperature Range: –40 to 200 °C (–40 to 150 °C for 15A)
Process Pressure Limit: Up to flange rating.
Ambient Temperature Range:
–40 to 85 °C (general type)
–30 to 80 °C (with Indicator/Totalizer)
–40 to 75 °C (CENELEC Explosion proof type)
–20 to 60 °C (CENELEC Intrinsic safety type)
–20 to 60 °C (JIS Flameproof type)
(Model UYF200 is affected by fluid temperature. See Figure 9.1-2)
Ambient Humidity Range:5 to 100% Relative Humidity (at 40 °C)
(non-condensing)
Power Supply Voltage:10.5 to 42 V DC
(Refer to Figure 9.1-1 Relationship Between Power Supply
Voltage and Load Resistance)
Output signal:Analog, Pulse
Both Analog and Pulse output can be obtained simultaneously.
In this case refer to the item 5.5.
Analog: 4 to 20 mA DC, 2-wire system.
Pulse: transistor contact (open drain), 3-wire system.
Contact rating: 30 V DC, 120 mA DC
Low level: 0 to 2 V DC.
Pulse frequency: Max. 6 kHz
Duty cycles: Approx. 50% (1:2 to 2:1)
Dumping time constant: 0 to 64 Sec (can be set in 8 steps)
Delay time: 0.5 Sec
Analog output circuit time constant: 0.3 Sec
69


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa UYFA21 Ultrasonic Vortex Flowmeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa UYFA21 Ultrasonic Vortex Flowmeter in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info