540489
12
Zoom out
Zoom in
Previous page
1/84
Next page
2-6
IM 1F5B2-01E
* Remote Type
Hazardous Location Non Hazardous Location
Flowmeter
Converter
(UYFA21)
UYF021
Signal Cable
Flowmeter
Detector
(UYF200-N)
+
SUPPLY
PULSE
+
A
B
C
A
B
C
+
Safety
Barrier 1
* Note 1
+
Safety
Barrier 2
* Note 1
Note 1: In any safety barrier used output current must be limited by a resistor ‘R’ such that Io=Uo/R
Note 2: The instrument modification or parts replacement by other than authorized representative of
Yokogawa Electric Corporation is prohibited and will void KEMA Intrinsically safe Certification.
2.10 Installation Precautions for CENELEC (KEMA)
Explosionproof
Suitable heat-resisting cables (heat-resisting over 90˚C) shall be used for the ULTRA
YEWFLO Model UYF200 Serise Ultrasonic Voltex Flowmeter when the ambient
temperature exceeds +70˚C and/or the process temperature exceeds 135˚C.
The cable entry devices shall be certified in type of protection flameproof enclosure “d”
and suitable for the conditions of use and correctly installed.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa UYF200 Ultrasonic Vortex Flowmeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa UYF200 Ultrasonic Vortex Flowmeter in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info