<8. Operation of DYFMVTool>
8-18
IM 01C25R51-01E
8.2.3 Apply Flow Conguration
Figure 8.18 Apply Flow Conguration Screen
Inordertodownloadthecongurationtothedevice,clickApply”.
ThenperformDownloadtoDevicefromDeviceDTM.(Refertosection6.2.3)
Refer to Chapter 5 and Figure 6.3.
NOTE
FollowingshowsDeviceGeneralParameters”whichisappliedtoOfineDatabase”.
Table 8.9 “Device General Parametersapplied to Ofine Database”
Simple Compensation Mode
Saturated steam
(Temperature)
Saturated steam
(Pressure)
Superheat steam
Gas temperature
pressure
compensation
Liquid temperature
compensation
Arithmetic Type Applied Applied Applied Applied Applied
Bias A
pplied(Always"0") Applied(Always"0") Applied(Always"0") Applied(Always"0") Applied(Always"0")
Gain A
pplied(Always"1") Applied(Always"1") Applied(Always"1") Applied(Always"1") Applied(Always"1")
Bias Input 1 A
pplied(Always"0") Applied(Always"0") Applied(Always"0") Applied(Always"0") Applied(Always"0")
Gain Input 1 A
pplied(Always"1") Applied(Always"1") Applied(Always"1") Applied(Always"1") Applied(Always"1")
Bias Input 2 A
pplied(Always"0") Applied(Always"0") Applied(Always"0") Applied(Always"0") Applied(Always"0")
Gain Input 2 A
pplied(Always"1") Applied(Always"1") Applied(Always"1") Applied(Always"1") Applied(Always"1")
Output Range.Unit Index Applied Applied Applied Applied Applied
V
olumetricFlowUnit Applied Applied Applied Applied Applied
Temperature Unit Applied Applied Applied Applied
Base Temperature Applied Applied
Pressure Unit Applied Applied
Base Pressure abs Applied
Density Unit Applied Applied Applied Applied
*1
Applied
Base Density Applied
*1
Applied
Deviation Applied
First Temperature Coef. Applied
Second Temperature Coef. Applied
A
pplied:TargetparameterisappliedbyDYFMVTool
*1: Not applied when output unit is Normal or Standard
134


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa FSA120 Flow Configuration Software at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa FSA120 Flow Configuration Software in the language / languages: English as an attachment in your email.

The manual is 12,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokogawa FSA120 Flow Configuration Software

Yokogawa FSA120 Flow Configuration Software Quick start guide - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info