<8. Operation of DYFMVTool>
8-7
IM 01C25R51-01E
Table 8.3 AGA 8 Mole Valid Range
# Component Mole Valid Range (Expanded Range)
1 CH4 Methane mole percent 0–100 %
2 N2 Nitrogen mole percent 0100 %
3 CO2 Carbon Dioxide mole percent 0–100 %
4 C2H6 Ethane mole percent 0100 %
5 C3H8 Propane mole percent 0–12 %
6 H2O Water mole percent 0–Dew Point %
*3
7 H2SHydrogenSuldemolepercent 0–100 %
8 H2 Hydrogen mole percent 0–100 %
9 CO Carbon Monoxide mole percent 0–3.0 %
10 O2 Oxygen mole percent 0–21 %
11 C4H10 i-Butane mole percent 0–6 %
*1
12 C4H10 n-Butane mole percent 0–6 %
*1
13 C5H12 i-Pentane mole percent 0–4 %
*2
14 C5H12 n-Pentane mole percent 0–4 %
*2
15 C6H14 n-Hexane mole percent 0–Dew Point %
*3
16 C7H16 n-Heptane mole percent 1–Dew Point %
*3
17 C8H18 n-Octane mole percent 2Dew Point %
*3
18 C9H20 n-Nonane mole percent 3–Dew Point %
*3
19 C10H22 n-Decane mole percent 4–Dew Point %
*3
20 He Helium mole percent 0–3.0 %
21 Ar ARGON 1–1.0 %
*1: ISOBUTANE (C4H10) and n-BUTANE (C4H10)’s sum cannot exceed 6 %.
*2: ISOPENTANE (C5H12) and n-Pentane (C5H12)s sum cannot exceed 4 %.
*3: Upper limit Dew Point is not checked by the tool.
(2) AGA8 Gross Characterization Method 1
Figure 8.5 Natural Gas Setup screen (2)
Table 8.4 Input & Valid Range (Expanded Range)
Contents Expanded Range Remarks
Mandatory
Real Gas Relative Density 0.554–0.87
at 14.73 psi abs 60 °F
(at 101.56 kPa abs and 15.56 °C)
CARBON DIOXIDE (CO2) mole 0–30 %
V
olumetricGrossHeatingValue
17.76–42.87 MJ/m3
(477–1150 BTU/ft3)
at 14.73 psi abs 60 °F
(at 101.56 kPa abs and 15.56 °C)
Optional
HYDROGEN (H2) mole 0–10 %
CARBON MONOXIDE (CO) mole 0–3 %
123


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa FSA120 Flow Configuration Software at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa FSA120 Flow Configuration Software in the language / languages: English as an attachment in your email.

The manual is 12,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokogawa FSA120 Flow Configuration Software

Yokogawa FSA120 Flow Configuration Software Quick start guide - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info