<6. Operation of FlowNavigator Program>
6-3
IM 01C25R51-01E
6.1.2 Data Flow Diagram
(1) EJXMVTool
EJXMVTool
XMV File
User Flow
Parameters
Device Flow
Parameters
Device General
Parameters
Compatible between different frame application
Compatible between HART and
F
OUNDATION fieldbus DTMs
Report File(csv)
User Flow Parameters
Device General Parameters
EJX910 HART/FOUNDATION fieldbus DTM
DNS/DFS File
Not compatible between different frame application
Not compatible between HART and
F
OUNDATION fieldbus DTMs
Device General
Parameters
Device Flow
Parameters
User Flow
Parameters
PRM File
(Note3)
Device General
Parameters (HART)
Import
Offline Parameter
Device Flow Parameters
Device Flow Parameters
Device
General Parameters
Offline Database
Device
General Parameters
Device Flow
Parameters
Online Parameter
Device
General Parameters
Device Flow Parameters
(Not displayed)
(Not displayed)
EJX Multivariable Transmitter
Device General
Parameters
Device Flow
Parameters
(Note1)
Sensor Input
F0602E.ai
DP, SP, ET
DP, SP, ET
(Auto Compensation/Basic Mode)
User Flow
Parameters
(Note2)
Device General Parameters
Flow Configuration Wizard
Obtain Flow Coefficient
Simulated Sensor Input
Flow Calculation Output
Process Value (DP,SP,ET)
Flow Coefficient (Flow, Density,
Viscosity,Gas Expansion Factor,
Discharge Coefficient, Reynolds No.)
Auto
Compensation
Mode
initialize
Apply
Start up /
Apply
Simulated Input *
Read Parameter *
Input*
Read/
Write*
Enter
Start up/
Open/
Save As
Open/
Save As
Save As
Open /
Export
Import/
Export
to Device*
Device*
Download
Lead from
*: Online function (executed while connect)
Note1) Device does not hold User Flow Parameter.
Note2) User Flow Parameters consist of fluid
information and operating condition.
Note3) Generated by FSA210.
Can be imported to HART DTM.
Figure 6.2 Data ow diagram of EJXMVTool
76


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa FSA120 Flow Configuration Software at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa FSA120 Flow Configuration Software in the language / languages: English as an attachment in your email.

The manual is 12,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokogawa FSA120 Flow Configuration Software

Yokogawa FSA120 Flow Configuration Software Quick start guide - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info