<3. INSTALLATION>
3-3
IM 01F06A00-01EN
Table 3.1 (b) Straight pipe length and recommendations (2)
D: Nominal diameter (mm)
Description Figure
Fluid vibration:
For a gas line which uses a position-type or roots-type blower
compressor or a high-pressure liquid line (about 1MPa or more)
which uses piston-type or plunger-type pump, fluid vibrations may
be produced.
In these case, install valve on the upstream side of digitalYEWFLO.
For inevitable fluid vibration, put a vibration damping device such
as throttling plate or expansion section in the upstream side of
digitalYEWFLO.
digitalYEWFLO
digitalYEWFLO
Piston-type or plunger pump:
Install the accumulator on the upstream side of digitalYEWFLO to
reduce uid vibrations.
digitalYEWFLO
Valve positon (T-type piping exist):
When pulsation causes by a T-type piping exist, install the valve on
the upstream of the owmeter.
Example: As shown in the figure, when the valve V1 is turned off,
the fluid flow throught B as to meter A the flow is zero. But due to
the pulsating pressure is detected, the meter is zero point become
uctuating. To avoid this, change the valve V1 location to V1'.
Note: In case of the Reduced Bore Type, moisture may be
remained upstream of the owmeter. Drain it appropriately.
Relocating
Valve (Off)
A
B
Flow
V1’ V1
digitalYEWFLO
Pressure and Temperature Taps:
Pressure tap outlet: install this tap between 2D and 7D on the
downstream side of a owmeter.
Temperature tap outlet: install this on the downstream side 1D to
2D away from a pressure tap.
Pressure tap
Temperature tap
Upstream
Flow
downstream
2 to 7D 1 to 2D
digitalYEWFLO
Mounting Gasket:
Avoid mounting gaskets which protrude into the pipe line. This may
cause inaccurate readings.
Use the gaskets with bolt holes, even if digitalYEWFLO is the wafer
type.
When using a spiral gasket (without bolt holes), confirm the size
with the gasket -manufacturer, as standard items may not be used
for certain ange ratings.
Pipeline Flange
Pipeline
No good
digitalYEWFLO
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokogawa DY Vortex Flowmeter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokogawa DY Vortex Flowmeter in the language / languages: English as an attachment in your email.

The manual is 5,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info