DS1054-057A P36
The only MTR that will drive the boiler must have the boiler icon:
Then add the thermostats as the Control Points and configure them.
Each zone thermostat, after being configured, must be “connected” both to the MTR of the corresponding zone
solenoid valve and to the boiler MTR.
To do so, touch button
+Configure the zone
.
A page like this will appear:
On the screen which appears, firstly uncheck the “Relay on thermostat” option
Firstly, touch button
Change the device to be controlled
at the label .
On the screen which appears, select the MTR with the solenoid valve symbol which
corresponds to the concerned zone and confirm.
Then touch button
Change the device to be controlled
at the label .
On the screen that appears, select the MTR with the boiler symbol and confirm.
Note: This boiler MTR must be connected on all of the system as a multi-zone relay.
Store the settings by pressing “Store”.
Go back to the point on the previous page, you must now transfer the configuration from the App to the
thermostat. To do this, similarly to what you are used to do with a remote control, tap on the button at the
bottom right, “Program” and, on the thermostat, press the button twice. At the end of the transfer, “PASS”
will be briefly displayed on the thermostat. If the transfer was not successful, “Err 16” will appear instead. Try
again, in this case.
Try again for all thermostats.
Note: The thermostats will be accessible remotely and locally via the Yno App. In this configuration the presence
of the Yokis Hub is indispensable.
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokis Thermarp 5454489 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokis Thermarp 5454489 in the language / languages: English as an attachment in your email.

The manual is 15.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokis Thermarp 5454489

Yokis Thermarp 5454489 User Manual - German - 40 pages

Yokis Thermarp 5454489 User Manual - Dutch - 40 pages

Yokis Thermarp 5454489 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info