DS1054-057A
10.4.3. How to extend the range
All YOKIS wireless receivers also serve as signal repeaters. By adding one or more modules, you can significantly
extend the wireless range by creating a wireless bus between the various modules on the system.
1) Create the wireless bus
Press the Connect button on module A once (the LED on module A will start flashing), then press the Connect
button on module B once (the connection between A and B is established and the 2 modules stop flashing).
The two presses must occur within a maximum time of 30 seconds.
Led
Connect
Led
Connect
Led
Connect
ABC
1 press 1 press
ETC
.
Repeat the same operation on modules B and C and so on, for all the others.
2) Pair the THERMARP thermostat with the module that controls the boiler
After creating the wireless bus, temporarily move the thermostat to near the module that controls the boiler. Pair
the THERMARP thermostat with the module that controls the boiler, following the steps described above.
3) Set the access point on the wireless bus
Place the thermostat in its final position.
Return to the Wireless menu of the THERMARP thermostat.
Use the buttons and to navigate the configuration menu to the AP E7 “Bus Access Point” submenu,
then tap the “Confirm” icon .
Note: The THERMARP thermostat may not be able to communicate
with the receiver if it is out of range. The message Err. 17 will
appear on the display in this case. See the “How to extend the
range” paragraph.
Once the mode has been validated, the message AP E7
starts flashing to confirm that the THERMARP thermostat
is in “Bus access point” pairing mode. Press the “Connect”
button of the module closest to the THERMARP thermostat
once to establish the connection. The PASS message
appears briefly to confirm the connection.
Led
Connect
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokis Thermarp 5454489 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokis Thermarp 5454489 in the language / languages: English as an attachment in your email.

The manual is 15.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokis Thermarp 5454489

Yokis Thermarp 5454489 User Manual - German - 40 pages

Yokis Thermarp 5454489 User Manual - Dutch - 40 pages

Yokis Thermarp 5454489 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info