P25DS1054-057A
8. REMOTE SWITCH-OFF
The device has two inputs (AUX) for connecting a potential-free contact to which a telephone dialler can be
connected, for example, to remotely switch the thermostat on and off using a telephone.
The contact can be in one of the following positions:
- open: normal operation (according to the programming set via keypad).
- closed: thermostat in off operation.
The remote off condition is indicated on the display by the flashing of the symbol to differentiate it from the
keypad off condition.
Note: This function must be operated via the Advanced Configuration (ADV) menu. The auxiliary input parameter
must be set to “diG”.
IMPORTANT: Remote off condition (contact closed) takes priority over any other programming and therefore
the thermostat will remain in the off condition until the contact returns to the open position.
9. THERMOSTAT RESET
This can be used to delete any settings made and reload the default settings.
Proceed as follows:
Disconnect the thermostat from the wall base and reconnect it.
While the buttons are flashing, keep the button pressed until “dEF” appears on the display.
Resetting to default settings will clears all settings in the configuration parameters:
Time and date
Edit programs
Change temperature (T1), T2, T3
Timer setting
Advanced menu configurations
IMPORTANT: Resetting to default parameters will not delete the wireless configurations made on the thermostat.
To delete the wireless configurations, see chapter “7.6.6. Def 25 : Thermostat wireless configuration reset”.
10. INSTALLATION
10.1. SAFETY WARNINGS
The following instructions must be observed when installing the product:
The product must be installed by a qualified professional, scrupulously respecting the wiring diagram.
Do not power or connect the product if any of its parts are damaged. Do not carry out repairs and contact
technical support directly.
Do not use the product for purposes other than those specified.
The device must be installed and put into operation in accordance with current legislation on electrical
systems.
The product can be used in a category 3 and grade 2 pollution measurement environment.
Where it is necessary to guarantee galvanic insulation towards the boiler, it is essential to install the REL1C
accessory (see diagram SD541-6054 in the MTR2000 product card).
10.2. HOW TO START THE THERMOSTAT
The Thermarp accessory is ideal for wall mounting. Alternatively, it can be installed on a flush mounting box
Mod. 503.
The thermostat must be installed at a height of about 1.5 m above the floor, protected from direct radiation,
away from doors, windows, heat sources, positions with excess or total lack of ventilation.
The YOKIS THERMARP thermostat runs on batteries (2 x 1.5 V AAA / LR03 type batteries).
Fix the base to the wall using the screws provided.
Open the rear compartment of the thermostat timer to insert the batteries, checking the polarity indicated
on the battery compartment.
1.
2.
1.
2.
3.
4.
5.
6.
1.
2.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yokis Thermarp 5454489 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yokis Thermarp 5454489 in the language / languages: English as an attachment in your email.

The manual is 15.95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yokis Thermarp 5454489

Yokis Thermarp 5454489 User Manual - German - 40 pages

Yokis Thermarp 5454489 User Manual - Dutch - 40 pages

Yokis Thermarp 5454489 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info