VARMAX - Installation, Use and Maintenance
B. NECESSARY ADJUSTMENT ACCESSORIES
Quantity
Appliance
reference
Order No.
Extension module kit (delivered with a
QAD 36 network sensor)
3 (4) AVS 75 059751
Communication kit 2 OCI 345 059572
Network sensor kit 1 QAx 36
059261 (QAZ 36)
059592 (QAD 36)
External sensor kit 1 QAC 34 059260
DHW sensor kit (diagram VX212) 1 QAZ 36 059261
C. CUSTOMER ELECTRICAL CONNECTION
Boiler No. 1:
INFORMATION:
If the insulating valve is not tted with an automatic reset, reconnect the
Q1.1 insulating valve closing contact on Y2.
L NY1 NY2L NL NL N
QX2 QX3 QX1 AUX2 AUX1
BX2
Gnd
BX3
Gnd
B3
Gnd
B9
Gnd
H1
Gnd
H5
Gnd
Mains supply 230
VAC 50 Hz
}
}
}
}
}
External sensor B9
Diagram VX212:
DHW sensor B3
DB MB
}
Flow sensor in
cascade B10
Alarm
relay
Insulating
valve Q1.1
LPB bus
Diagram VX212
only
Diagrams: VX202 / VX212
page 2 / 9
107


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Varmax at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Varmax in the language / languages: English as an attachment in your email.

The manual is 17,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Varmax

Ygnis Varmax Usermanual and installation guide - Dutch - 144 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info