Edition: 06 / 2015 Page 31 / 146
VARMAX - Installation, Use and Maintenance
4.10.4. Connection to a C13 or C33 air vent
Type C13 connection:
Air inlet and gas extraction via separate ducts connected to a horizontal
concentric terminal (air vent).
Type C33 connection:
Air inlet and gas extraction via separate ducts connected to a vertical
concentric terminal.
!
IMPORTANT:
Connecting a VARMAX boiler in C13 or C33 con guration requires use of
the "Terminal kit" comprising a terminal, a dual- ow adaptor and a male
adaptor
ø150 / female adaptor ø160 (reference 041421).
gure 20 - Type C13 connection gure 21 - Type C33 connection
The table below shows the maximum straight lengths authorised for air and
ue-gas ducts.
MODELS
120 140 180 225
L1 (air) 16.5 lm 13.5 lm
L2 ( ue-gases) 17.5 lm 14.5 lm
The lengths indicated include the lengths of the concentric terminal.
U0501398-#
U0501471-#
L2
L1
L1
L2
ø160
ø150
ø160
ø150
Ensure the slope from the concentric
terminal is 3°.
450 mm
maxi
450 mm
maxi
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Varmax at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Varmax in the language / languages: English as an attachment in your email.

The manual is 17,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Varmax

Ygnis Varmax Usermanual and installation guide - Dutch - 144 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info