LRR 47 - 59 & LRR-GF 47 - 52
Maat- en constructiewijzigingen voorbehouden! 13 editie 30.01.2009
Technische gegevens LRR, gas E
LRR 47484950515253545556575859
Vermogens
Nuttig vermogen qN (80/60°C) max. 1150 1400 1650 2000 2500 3000 3800 4500 5400 6300 7400 8600 10000
min. 358 358 366 484 720 726 880 1160 1473 1582 1935 2332 2907
Warmtebelasting qF max. 1242 1530 1815 2189 2725 3289 4166 4929 5894 6861 8055 9328 10795
min.
3
372 372 381 503 749 756 916 1208 1532 1647 2014 2425 3023
Modulatie
3
30% 24% 21% 23% 27% 23% 22% 25% 26% 24% 25% 26% 28%
Rendementen
Thermisch rendement 60 / 80 °C 100% % 92.6 91.5 90.9 91.3 91.7 91.2 91.2 91.3 91.6 91.8 91.9 92.2 92.6
Thermisch rendement 60 / 80 °C 30% % 96.0 95.8 95.5 95.7 96.0 95.6 95.7 95.8 95.9 95.8 95.8 95.9 96.1
Thermisch rendement 60 / 80 °C min qF % 96.0 96.0 96.0 96.1 96.1 96.0 96.1 96.1 96.1 96.1 96.1 96.1 96.2
Rendement DIN4702-8, 60 / 75 °C
ξ
N
%
95.5 95.2 94.9 95.1 95.4 95.0 95.1 95.1 95.3 95.3 95.3 95.4 95.6
Debieten
Gasdebiet, gas E (G20) max.
1,2
124.6 153.5 182.1 219.7 273.4 330.0 418.0 494.6 591.4 689 808 936 1083
min.
1,2
37.4 37.4 38.2 50.5 75.2 75.9 92.0 121.2 153.8 165 202 243 303
Rookgasdebiet max. nat 0.52 0.64 0.76 0.91 1.14 1.37 1.74 2.06 2.46 2.87 3.36 3.89 4.51
min. nat
1,3
0.16 0.16 0.16 0.21 0.31 0.32 0.38 0.50 0.64 0.69 0.84 1.01 1.26
Rookgasgegevens, verliezen
Druk verbrandingskamer max. mbar 6.30 9.68 9.67 10.45 10.35 10.26 11.01 10.18 10.91 12.46 14.40 16.03 17.48
Rookgastemperatuur bij 80/60 °C
max. 170 193 205 196 188 198 199 197 191 186 185 179 170
min.
3
Rookgasverliezen bij 80/60 °C max. % 7.2 8.4 9.0 8.5 8.2 8.7 8.7 8.6 8.3 8.1 8.0 7.7 7.3
Stilstandverliezen qB
70 °C
W
1326 1326 1489 1665 1972 2197 2724 3413 3827 4511 5118 5582 6043
Hydraulische gegevens
Waterweerstand
ξ
t=15K
47 69 96 68 107 48 78 109 157 84 116 80 108
ξ
t=20K 26 39 54 39 60 27 44 62 89 47 65 45 61
Waterdebiet max. 66 80 95 115 143 172 218 258 309 361 424 493 573
Bedrijfstemperaturen max.
TVB
Gegevens volgens EN303-3 bij: 3zugskessel, V-04/08 & 12/08
- lamda=1.15, CO2=10% GG
- T-Lucht=20°C, rel. hum.=60%, p-baro=100kPa
1: Hi = 9.97 kWh/nm3
2: nm3 bij 0°C, 1013 mbar
3: S max = 10 mg / nm3
95
m3/h
mbar
°C
kg/s
110
95
kW
kW
nm
3
/h
°C
90
100
110
120
130
140
150
160
170
180
190
200
210
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000
QN [kW]
[°C]
GG
LRR49
LRR50
LRR51
LRR54
LRR59
LRR52
LRR53
LRR48
LRR47
LRR55 LRR56 LRR57
LRR58
Temperaturen rookgassen LRR, aardgas bij schone ketel
© Copyright YGNIS AG CH-Ruswil
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Pyronox LRR-GF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Pyronox LRR-GF in the language / languages: Dutch as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info