638656
10
Zoom out
Zoom in
Previous page
1/48
Next page
LR, LRK, LR-NT, LRK-NT 21 - 32
We reserve the right to make changes to dimensions and construction 8 edition 30.10.2007
4.5. Dimensions of custom made models
The following custom made models are available on request. They are however subject to different delivery times!
4.5.1. Vertical flue connection Pyronox LR and LR-NT
Pyronox LR 21 22 23 24 25 26 27 28 29 30 31 32
Flue outside
diameter
e mm 200 250 250 250 250 300 350 350 350 400 450 500
Flue height
f
1
mm60100100100100100808080808080
Flue position n mm 1702 1812 1812 2025 2025 2106 2459 2459 2819 3004 3260 3521
Overall length L
1
mm 2025 2140 2140 2360 2360 2465 2859 2859 3274 3484 3766 4051
Overall height H
1
mm 1370 1470 1470 1555 1555 1645 1730 1730 1805 1870 1990 2080
16/10/07 RR
The other dimensions are identical to those of the standard range.
4.5.2. Different operating pressures
Pyronox LR and LRK boilers can be provided for the operating pressures of 4, 8 and 10 bar-g. Their dimensions
and performances are identical to those of the standard range of 6 bar-g, but their weights are different:
Empty weights
Pyronox LR 21 22 23 24 25 26 27 28 29 30 31 32
4 bar
Gk
g
1127 1439 1439 1802 1802 1959 2302 2302 2753 3194 3937 4440
8 bar
G kg 1190 1606 1606 1979 1979 2159 2715 2715 3286 3761 4601 5221
10 bar
Gk
g
1277 1608 1608 2227 2227 2436 2746 2746 3362 4053 4980 5706
16/10/07 RR
P
y
ronox LR-NT 212223242526272829303132
4 bar
G kg 1220 1561 1561 1950 1950 2121 2494 2494 2989 3466 4270 4821
8 bar
G kg 1283 1728 1728 2127 2127 2321 2907 2907 3522 4033 4934 5602
10 bar
Gk
g
1370 1730 1730 2375 2375 2598 2938 2938 3598 4325 5313 6087
16/10/07 RR
Empty weights
Pyronox LRK 212223242526272829303132
4 bar
Gk
g
1447 1749 1749 2152 2152 2379 2792 2792 3313 3934 4857 5510
8 bar
G kg 1510 1916 1916 2329 2329 2579 3205 3205 3846 4501 5521 6291
10 bar
Gk
g
1597 1918 1918 2577 2577 2856 3236 3236 3922 4793 5900 6776
16/10/07 RR
P
ronox LRK-NT 21 22 23 2
4
25 26 27 28 29 30 31 32
4 bar
G kg 1540 1871 1871 2300 2300 2541 2984 2984 3549 4206 5190 5891
8 bar
G kg 1603 2038 2038 2477 2477 2741 3397 3397 4082 4773 5854 6672
10 bar
Gk
g
1690 2040 2040 2725 2725 3018 3428 3428 4158 5065 6233 7157
16/10/07 RR
4.5.3. LRK sanitary version
The recuperators of the Pyronox LRK 21 to 29 can be provided as sanitary version with water collectors and -
connections made of stainless steel. Their dimensions and performances are identical to those of the standard
range, apart from the dimensions of the water connections (see table in chapter 4.4.2).
© Copyright YGNIS AG CH-Ruswil
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Pyronox LRK-NT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Pyronox LRK-NT in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Pyronox LRK-NT

Ygnis Pyronox LRK-NT Usermanual and installation guide - Dutch - 46 pages


The manual is sent by email. Check your email