LR, LRK, LR-NT, LRK-NT 21 - 32
Maat- en constructiewijzigingen voorbehouden! 20 editie 14.1.2008
4.7. Nadere specificaties voor Pyronox LRK en LRK-NT
4.7.1. Pyronox LRK
Technische gegevens rekuperator (huisbrandolie)
LRK 212223242526272829303132
Vermogens
Nuttig vermogen qN (30 / 35°C)
max.
1
42 42 47 50 59 64 82 96 130 141 179 237
min.
1
18 22 22 29 29 39 48 48 55 69 96 106
Rendementen
Thermisch rendement 30 / 35 °C
100%
1
%
98.2 98.5 98.3 98.9 98.3 99.2 98.9 98.3 98.2 98.3 98.4 98.2
Thermisch rendement 30 / 35 °C
30%
2
%
102.9 102.8 102.9 102.7 103.0 102.6 102.7 102.9 103.1 103.0 102.9 103.2
Rendement DIN4702-8, 60 / 75 °C
η
N
%
102.4 102.4 102.4 102.5 102.5 102.4 102.4 102.4 102.8 102.7 102.6 102.7
Rookgasgegevens, verliezen
Maximale druk uitgang rookgassen
max
mbar
2.75 1.29 1.56 1.85 2.51 1.41 1.26 1.68 2.77 2.08 2.20 2.15
Totale druk verbrandingskamer
max
mbar
8.60 5.42 6.51 6.78 9.11 6.64 7.55 9.90 12.24 11.33 12.36 11.48
Rookgastemperatuur bij 30 / 35 °C
max.
1
51 48 49 47 49 47 47 49 50 49 48 50
min.
1
35 35 35 36 36 37 36 36 36 36 36 36
Rookgasverliezen bij 30 / 35 °C
max.
1
%
1.6 1.5 1.6 1.4 1.5 1.4 1.5 1.6 1.7 1.6 1.7 1.6
Stilstandverliezen qB
70 °C
W
824 926 926 1073 1073 1239 1447 1447 1645 1831 2166 2427
Hydraulische gegevens
Waterweerstand
Δ
t=5K
22 29 38 29 41 33 40 54 64 52 53 66
Δt=10K
6 7 10 7 10 8 10 14 16 13 13 17
Waterdebiet
max. 7.2 7.2 8.1 8.6 10.1 11.0 14.1 16.5 22.3 24.2 30.7 40.6
min. 1.8 2.0 2.0 2.5 2.5 2.7 4.1 4.1 5.6 6.0 7.7 10.2
Condensaat
Debiet
max.
L / h
13.5 16.0 17.5 21.5 22.5 29.5 34.5 37.0 45.0 55.0 73.0 84.0
Gegevens bij:
3zugskessel, V-01/07
- lamda=1.2, CO2=12.7%
OG
- T-Lucht=20°C, rel. hum.=60%, p-baro=100kPa
1: Ketel bei 60 / 80 °C
2: Ketel bei 50 / 70 °C
m3/h
kW
mbar
°C
Technische gegevens rekuperator (gas E)
LRK 212223242526272829303132
Vermogens
Nuttig vermogen qN (30 / 35°C)
max.
1
67 72 79 87 101 110 143 163 208 239 313 378
min.
1
12 15 15 22 22 33 38 39 45 57 90 109
Rendementen
Thermisch rendement 30 / 35 °C
100%
1
%
102.1 103.3 102.7 103.6 102.9 103.9 103.6 102.9 102.4 102.9 103.2 102.4
Thermisch rendement 30 / 35 °C
30%
1
%
107.5 107.5 107.6 107.6 107.6 107.7 107.7 107.7 107.7 107.8 107.8 107.8
Rendement DIN4702-8, 60 / 75 °C
η
N
%
107.0 107.1 107.1 107.2 107.2 107.3 107.3 107.2 107.2 107.3 107.3 107.2
Rookgasgegevens, verliezen
Maximale druk uitgang rookgassen
max
mbar
2.81 1.32 1.60 1.89 2.57 1.44 1.29 1.71 2.83 2.13 2.25 2.20
Totale druk verbrandingskamer
max
mbar
8.78 5.54 6.66 6.92 9.31 6.77 7.70 10.10 12.50 11.57 12.60 11.70
Rookgastemperatuur bij 30 / 35 °C
max.
1
50 48 49 47 49 46 47 49 50 49 48 50
min.
1
32 32 32 32 32 33 32 33 32 32 33 33
Rookgasverliezen bij 30 / 35 °C
max.
1
%
1.61.51.51.41.61.41.51.61.61.61.61.6
Stilstandverliezen qB
70 °C
W
824 926 926 1073 1073 1239 1447 1447 1645 1831 2166 2427
Hydraulische gegevens
Waterweerstand
Δt=5K
53 89 107 88 117 100 120 157 163 149 161 168
Δ
t=10K
13 22 27 22 29 25 30 39 41 37 40 42
Waterdebiet
max. 11.5 12.3 13.5 14.9 17.3 18.9 24.5 27.9 35.7 41.0 53.7 64.8
min. 1.8 2.0 2.0 2.5 2.5 2.7 4.1 4.1 5.6 6.0 7.7 10.2
Condensaat
Debiet
max.
L / h
38.0 48.0 49.0 61.0 64.0 81.0 98.0 102.0 123.5 151.0 199.0 242.0
Gegevens bij:
3zugskessel, V-01/07
- lamda=1.15, CO2=10%
GG
- T-Lucht=20°C, rel. hum.=60%, p-baro=100kPa
1: Ketel bei 60 / 80 °C
kW
mbar
°C
m3/h
© Copyright YGNIS AG CH-Ruswil
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Pyronox LRK-NT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Pyronox LRK-NT in the language / languages: Dutch as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Pyronox LRK-NT

Ygnis Pyronox LRK-NT Usermanual and installation guide - English - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info