LR, LRK, LR-NT, LRK-NT 21 - 32
We reserve the right to make changes to dimensions and construction 38 edition 30.10.2007
© Copyright YGNIS AG CH-Ruswil
6.8. Flue gas system
The pertinent rules of technology and good practice as well as the country-specific regulations and valid
standards must be observed.
The Pyronox LR boilers have been developed using the latest technologies. The perfect balance existing between
boiler and chimney ensures optimal fuel use and economical system operation as a result.
6.8.1. Section determination
Sections must be calculated for boilers without draught.
Fuel type, power output, combustion gas temperature and quantity, chimney construction and height are all
important elements in determining sizes.
6.8.2. Flue gas tubes Pyronox LR, LR-NT
We recommend the use of flue gas tubes made from acid-resistant, non-corrosive materials. The tube must be
laid and introduced in the chimney to an inclination of 30-45° to minimize pressure loss. The tube will have to be
inserted in such a way as to prevent any condensation reversal from the chimney down into the boiler. To avoid
vibration transmission, combustion gas tubes must be fitted with adequate sleeve tubes or clamps. Connections
exceeding 1 m in length should be insulated.
At the same time, ensure that the measuring pipes extend beyond the insulation and that flanges and cleaning
covers remain accessible.
The chimney must be designed so that it is gas and pressure-tight as well as moisture-insensitive and acid-
resistant.
6.8.3. Flue gas tubes Pyronox LRK, LRK-NT
Depending on the return temperature, the flue gases are cooled below the dew point in the recuperator and leave
the boiler with 100% moisture. As a result of the flue gas cooling in the flue gas tube, more condensate is
eliminated. The flue gas unit must therefore be absolutely acid-resistant and condensate-tight, in addition to being
gas and pressure-tight.
The tube must be laid and introduced in the chimney to an inclination of 30-45° to minimize pressure loss. To
avoid vibration transmission, combustion gas tubes must be fitted with adequate sleeve tubes or clamps.
Connections exceeding 1 m in length should be insulated. At the same time, ensure that the measuring pipes
extend beyond the insulation and that flanges and cleaning covers remain accessible.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Pyronox LR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Pyronox LR in the language / languages: English as an attachment in your email.

The manual is 1,29 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Pyronox LR

Ygnis Pyronox LR Installation Guide - English, German - 40 pages

Ygnis Pyronox LR Installation Guide - German - 32 pages

Ygnis Pyronox LR Installation Guide - Dutch - 40 pages

Ygnis Pyronox LR Usermanual and installation guide - Dutch - 46 pages

Ygnis Pyronox LR Installation Guide - French, Italian, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info