638653
14
Zoom out
Zoom in
Previous page
1/32
Next page
3.4.3 Pyronox LR (Heizöl, Low-NOx Ausführung mit integrierter Abgasrückführung (ARF)
Typ 21 22 23 24 25 26 27 28 29 30 31 32
Leistung / Belastung
Nennwärmeleistung qN**
80/60°C
4
min
2,4
min
3,4
min
kW
kW
kW
380
176
142
430
225
180
470
225
180
585
294
237
600
294
237
755
412
336
935
506
409
935
506
409
1185
584
478
1455
735
598
1865
1025
842
2325
1072
875
Feuerungswärme-
leistung qF**
max
2
min
3
min
kW
kW
kW
413
186
149
462
237
189
509
237
189
631
310
249
649
310
249
813
434
352
1008
533
429
1008
533
429
1284
616
502
1575
774
627
2009
1079
882
2532
1129
917
Wirkungsgrade
Gesamtwirkungsgrad
60/80 °C
50/70 °C
100
3
30
%
%
92,1
95,3
92,9
95,2
92,5
95,3
92,7
95,2
92,5
95,3
92,9
95,3
92,7
95,2
92,7
95,3
92,3
95,2
92,4
95,2
92,8
95,3
91,8
95,3
Stoffströme
Heizöldurchsatz
1
max
1,3
min
kg/h
kg/h
34,8
15,6
39,0
15,9
42,9
15,9
53,3
21,0
54,8
21,0
68,6
29,7
85,1
36,2
85,1
36,2
108,3
42,4
132,9
52,9
169,5
74,5
213,2
77,4
Abgasmassenstrom max
3
min
kg/s
kg/s
0,18
0,06
0,20
0,08
0,22
0,08
0,27
0,11
0,28
0,11
0,35
0,15
0,43
0,18
0,43
0,18
0,55
0,22
0,68
0,27
0,87
0,38
1,09
0,40
Abgasdaten
Abgasseitiger Widerstand max mbar 4,18 3,13 3,79 4,76 5,03 5,33 5,89 5,89 6,75 7,63 7,54 7,57
Abgastemperatur bei
80/60 °C
max
2
min
3
min
5
min
°C
°C
°C
°C
183
121
111
100
166
121
111
100
176
121
111
100
172
121
112
100
175
122
112
100
168
121
111
100
171
123
113
100
171
123
113
100
179
124
115
100
178
124
115
100
168
123
113
100
189
124
113
100
Abgasverlust bei
80/60 °C
max
%
7,6
6,8
7,3
7,1
7,2
6,9
7,1
7,1
7,5
7,5
7,0
8,0
Bereitschaftsverlust
qB 70°C W 781 883 883 1020 1020 1177 1382 1382 1565 1742 2073 2330
Wasserseitige Daten
Widerstand 10 K
20 K
mbar
mbar
22
6
28
7
33
8
51
13
54
14
85
21
54
14
54
14
86
21
62
16
103
26
50
13
Durchfluss max
min
m
3
/h
m
3
/h
32,6
0,0
36,9
0,0
40,4
0,0
50,3
0,0
51,6
0,0
64,9
0,0
80,3
0,0
80,3
0,0
101,8
0,0
125,0
0,0
160,2
0,0
199,8
0,0
Betriebstemperaturen
Vorlauftemperatur max °C 95 95 95 95 95 95 95 95 95 95 95 95
Sicherheitstemp. STB max °C 110 110 110 110 110 110 110 110 110 110 110 110
**) Das Angebot verschiedener Brennertechnologien erfordert in jedem einzelnen Fall das Überprüfen der Leistungsdaten.
Werte nach EN304 bei:
- lamda = 1,2, C02 = 12,7%
- T-Luft = 20°C, rel. Feuchtigkeit = 60%
- p-baro = 100 kPa
- 1 Hu=11,85 kWh/kg
- 2 Schwefelgehalt bis 0,2%
- 3 Schwefelgehalt bis max. 0,05% (500 ppm)
- 4 mit 15% interner Abgasrückführung, konstante Menge auch bei Teillast
- 5 Schwefelgehalt bis max. 50 ppm
14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ygnis Pyronox LR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ygnis Pyronox LR in the language / languages: German as an attachment in your email.

The manual is 2,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ygnis Pyronox LR

Ygnis Pyronox LR Usermanual and installation guide - English - 48 pages

Ygnis Pyronox LR Installation Guide - English, German, Dutch - 40 pages

Ygnis Pyronox LR Usermanual and installation guide - Dutch - 46 pages

Ygnis Pyronox LR Installation Guide - French, Italian, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info