A Plug-in Voice cannot be selected even when a Plug-in Board has been installed.
Check whether the SLOT lamp (from SLOT1 - 3) corresponding to the selected PLG button ([PLG1] - [PLG3]) is turned on
or off.
When selecting a User bank, are any Voices stored into the User bank?
In the default settings, User banks for Plug-in Voice contain no Voices. You must the select the Preset bank or create a
User Voice.
Check whether the PLG which corresponds to the PLG100-XG slot is selected or not.
The Voice on the PLG100-XG cannot be selected in the Voice mode or Performance mode.
Check whether the PLG which corresponds to the PLG100-VH slot is selected or not.
The PLG100-VH contains no Voices for selection, since it is an Effect Plug-in Board.
The Plug-in Board does not work.
Is the lamp of the corresponding slot number to which the Plug-in board has been installed lit? (page 18)
Has the PLG100-VH been installed to slot 2 or 3?
The PLG100-VH can be installed only to slot 1.
Has the PLG100-XG been installed to slot 1 or 2?
The PLG100-XG can be installed only to slot 3.
Data communication between the computer and the S90 ES does not work properly.
Check whether the Port setting on the computer is appropriate or not.
Is the cable setting (MIDI, USB, mLAN) in the Utility mode appropriate?
The S90 ES does not sound properly even when playing back the song data on the computer or the
MIDI instrument connected to the S90 ES.
Make sure to set the S90 ES to the Multi mode. To play back the multiple channels simultaneously, select multi mode.
(page 70)
MIDI bulk data transmission/reception does not work properly.
Is Bulk data receive protection enabled?
Turn the Receive Bulk parameter to “on.”
When receiving recorded data with the internal Bulk Dump function, the device number must be set to the same value as
that used when transmitting/recording.
When transmission does not work properly, is the device number of the MIDI instrument connected to the S90 ES set to
match the DeviceNo. parameter?
When using the Voice Editor/Multi Part Editor, have you set a sufficient Dump Interval?
The Dump Interval in the Editor Setup dialog must be set to 20ms or greater. For details refer to the PDF manual included
with the Editor.
Data cannot be saved in the USB storage device
Is the connected USB storage device write protected? (Write-protect should be set to off for saving data.)
Is the connected USB storage device properly formatted?
Cannot enter the Edit mode
Is the Category Search function turned on?
After exiting from the Category Search function, press the [EDIT] button.
Is the S90 ES in the File mode?
After exiting from the File mode, press the [EDIT] button.
[VOICE] [F2] BANK (page 127)
[UTILITY] [F5] MIDI [SF4] OTHER MIDI IN/OUT(page 166)
[UTILITY] [F5] MIDI [SF2] SWITCH RcvBulk (page 166)
[UTILITY] [F5] MIDI [SF1] CH DeviceNo (page 166)
[UTILITY] [F5] MIDI [SF1] CH DeviceNo (page 166)
[FILE] [F1] CONFIG [SF2] FORMAT (page 168)
192


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha S90ES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha S90ES in the language / languages: English as an attachment in your email.

The manual is 5,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha S90ES

Yamaha S90ES User Manual - German - 204 pages

Yamaha S90ES User Manual - Dutch - 204 pages

Yamaha S90ES User Manual - French - 204 pages

Yamaha S90ES User Manual - Portuguese - 204 pages

Yamaha S90ES User Manual - Spanish - 198 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info