P-155 Manuale di istruzioni
63
Formato dati MIDI
4. PROGRAM CHANGE
Data format: [CnH] -> [ppH]
CnH = Program event (n = channel number)
ppH = Program change number
P. C.#=Program Change number
Some devices use a “0 to 127” numbering system for program
change messages. Since the instrument uses a “1 to 128”
numbering system, you will need to subtract 1 from the trans-
mitted program change numbers to select the appropriate
sound: e.g. to select P.C.#1 in the list above, transmit program
change number 0.
5. PITCH BEND CHANGE
[EnH] -> [ccH] -> [ddH]
ccH = LSB
ddH = MSB
6. SYSTEM REALTIME MESSAGES
[rrH]
F8H: Timing clock
FAH: Start
FCH: Stop
FEH: Active sensing
Caution: If an error occurs during MIDI reception, the Sustain,
Sostenuto, and Soft effects for all channels are turned off and
an All Note Off message occurs.
7. SYSTEM EXCLUSIVE MESSAGES
(Yamaha MIDI Format)
Panel Data Transmit
Data format: [F0H] -> [43H] -> [0nH] -> [7CH] -> ... -> [F7H]
F0H, 43H, 0nH, 7CH (n: channel number)
00H, LLH (data length)
43H, 4CH, 20H, 20H (CL)
43H, 4CH, 50H, 27H, 30H, 38H
3xH, 3yH (version x.y)
[PANEL DATA]
[CHECK SUM (1byte)] = 0-(43H+4CH+20H+......+Data end)
F7H (End of Exclusive)
• Panel Data Contents
•Panel data send requests cannot be received.
8. SYSTEM EXCLUSIVE MESSAGES
(Universal System Exclusive)
(1) Universal Realtime Message
Data format: [F0H] -> [7FH] -> [XnH] -> [04H] -> [01H] ->
[llH] -> [mmH] -> [F7H]
MIDI Master Volume
•Simultaneously changes the volume of all channels.
When a MIDI master volume message is received, the volume
only has affect on the MIDI receive channel, not the panel
master volume.
F0H = Exclusive status
7FH = Universal Realtime
7FH = ID of target device
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
llH = Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
or
F0H = Exclusive status
7FH = Universal Realtime
XnH = When n is received n=0–F, whichever is received.
X = irrelevant
04H = Sub-ID #1=Device Control Message
01H = Sub-ID #2=Master Volume
llH = Volume LSB
mmH =
Volume MSB
F7H = End of Exclusive
VoiceName MSB LSB P.C.#
GRAND PIANO 1 0 122 1
GRAND PIANO 2 0 112 1
ELECTRIC PIANO 1 0 122 6
ELECTRIC PIANO 2 0 122 5
JAZZ ORGAN 0 122 17
CHURCH ORGAN 1 0 123 20
STRINGS 1 0 122 49
STRINGS 2 0 125 50
CHURCH ORGAN 2 0 122 20
HARPSICHORD 0 122 7
E.CLAVICHORD 0 122 8
VIBRAPHONE 0 122 12
CHOIR 0 122 53
GUITAR 0 122 25
WOOD BASS 0 122 33
BASS & CYMBAL 0 124 33
E.BASS 0 122 34
Data Transmission Reception
F8H
Transmitted every
96 clocks
Received as 96-clock tempo timing
when MIDI clock is set to External.
FAH Song start
Song start
Not received when the MIDI clock is
set to Internal.
FCH Song stop
Song stop
Not received when the MIDI clock is
set to Internal.
FEH
Transmitted every
200 milliseconds
If a signal is not received via MIDI for
more than 400 milliseconds, the
same processing will take place for
All Sound Off, All Notes Off and Reset
All Controllers as when those signals
are received.
(1) 1’st Voice
(2) Dual On/Off
(3) Dual Voice
(4) Dual Balance
(5) Dual Detune
(6) Dual Voice1 Octave
(7) Dual Voice2 Octave
(8) Dual Voice1 Effect Depth
(9) Dual Voice2 Effect Depth
(10) Split On/Off
(11) Split Voice
(12) Split Point
(13) Split Balance
(14) Split Voice1 Octave
(15) Split Voice2 Octave
(16) Split Voice1 Effect Depth
(17) Split Voice2 Effect Depth
(18) Split Sustain Mode
(19) Reverb Type 1
(20) Reverb Type 2
(21) Reverb Depth 1
(22) Reverb Depth 2
(23) Effect Type 1
(24) Effect Type 2
(25) Effect Depth
(26)
(27) Touch Sensitivity
(28) Fixed Data
(29) AUX Pedal
(30) Soft Pedal Depth
(31) Absolute tempo low byte
(32) Absolute tempo high byte
(33) Key-Off Sampling Depth
(34) Damper Resonance On/Off
(35) Damper Resonance Depth
63


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha P-155 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha P-155 in the language / languages: Italian as an attachment in your email.

The manual is 3,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha P-155

Yamaha P-155 User Manual - English - 72 pages

Yamaha P-155 User Manual - German - 72 pages

Yamaha P-155 User Manual - Dutch - 72 pages

Yamaha P-155 User Manual - Danish - 72 pages

Yamaha P-155 User Manual - French - 72 pages

Yamaha P-155 User Manual - Polish - 72 pages

Yamaha P-155 User Manual - Portuguese - 72 pages

Yamaha P-155 User Manual - Swedish - 72 pages

Yamaha P-155 User Manual - Spanish - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info