Owner’s Manual
[F3] EVENT (Event Job)
n Before executing the Event Job, make sure that you specify the track and range (measure : beat : clock) to which the Job is applied. Please note that the track to be specified
varies depending on the Job.
01: Shift Clock
This Job shifts all data events in the specified range forward or backward by the specified number of clocks.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16, TMP, SCN, all) and range of measures/beats/clocks over which the Job is
applied.
Clock Determines the amount by which the data will be delayed or advanced in measures, beats, and clocks.
Settings: 000:0:000 – 999:3:479
Direction Determines the direction in which the data will be shifted. ADVANCE moves the data toward the beginning of
the sequence, while DELAY shifts the data toward the end of the sequence.
Settings: Advance, Delay
02: Copy Event
This Job copies all data from a specified source
range to a specified destination location.
Execute this Job after setting:
• Source track (01 – 16, TMP, SCN, all)
• Source range (measure : beat : clock)
• Destination track (01 – 16, TMP, SCN, all)
• Destination range (measure : beat : clock)
• Top measure of destination
• Count (number of times data is to be copied)
NumberOfTimes Determines the number of times the data is copied.
Settings: 01 – 99
When Copy Event is executed, any data already existing at the Destination location will be overwritten.
03: Erase Event
This Job clears all specified events from the specified range, effectively producing a segment of silence.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16, TMP, SCN, all) and range of measures/beats/clocks over which the Job is
applied.
Event Type Determines the event type to be erased. All events are cleared when ALL is selected. Individual control change
numbers can be specified when erasing control change events.
Settings:
When TR is set to 01 – 16: Note (Note events), PC (Program Change), PB (Pitch Bend), CC (Control Change)*, CAT (Channel
Aftertouch), PAT (Polyphonic Aftertouch), EXC (System Exclusive), All (all events)
When TR is set to “TMP” (Tempo): TMP (tempo)
When TR is set to “SCN” (Scene): SceneMemory (Scene change information), TrackMute (Track mute setting change information)
* You can also specify the CC No. (Control Change number).
04: Extract Event
This Job moves all instances of specified event data from a specified range of a track to the same range in a
different track.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16) and range of measures/beats/clocks over which the Job is applied.
EventType Selects the event type to be extracted. Specific note and control change numbers can also be specified as
required.
Settings: Note, PC (Program Change), PB (Pitch Bend), CC (Control Change), CAT (Channel Aftertouch), PAT (Polyphonic
Aftertouch), EXC (System Exclusive)
TR Determines the destination track (01 – 16).
05: Create Continuous Data
This Job creates continuous pitch bend or control change data over the specified range.
TR (Track)
001 : 1 : 000 – 999 : 4 : 479
Determines the track (01 – 16, TMP, all) and range of measures/beats/clocks over which the Job is applied.
EventType Determines the event type to be created.
Settings: PB (Pitch Bend), CC (Control Change)*, CAT (Channel Aftertouch), EXC (System Exclusive), TMP (Tempo)
* You can also specify the CC No. (Control Change number).
Data (Data Range) Determines the lower and upper limits for the data range to be created. The left value is the lower limit, and the
right value is the upper limit.
Settings: When Event Type is set to PB: -8192 – +8191
When Event Type is set to TMP: 1.0 – 300.0
When Event Type is set to other: 0 – 127
Clock Determines the number of clocks to be inserted between each created event.
Settings: 001 – 999
Curve Determines the “curve” of the continuous data.
Refer to the graph for approximate curve shapes.
Settings: -16 – +16
Source track and range in measures, beats, and clocks
Destination track and the top (measure, beat, and clock)
of the destination.
CAUTION
Curve = +16 Curve = 0 (linear) Curve = -16
Start point
End point
This distance specified by Clock
186


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha MO8 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha MO8 in the language / languages: English as an attachment in your email.

The manual is 5,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha MO8

Yamaha MO8 User Manual - German - 239 pages

Yamaha MO8 User Manual - French - 239 pages

Yamaha MO8 User Manual - Portuguese - 240 pages

Yamaha MO8 User Manual - Spanish - 240 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info