Specifications
32
EMX512SC/EMX312SC/EMX212S
Specifications
General Specifications
Output RL Conditions US AU EU UNIT
Maximum Output Power SPEAKERS OUT
EMX512SC
4
Both ch drive, 1 kHz,
THD+N 0.5%
MIN
500 500 500
W
8 350 350 320
EMX312SC
4 300 300 300
8 190 190 180
EMX212S
4 220 220 220
8 130 130 130
Input Output RL Conditions MIN TYP MAX UNIT
Frequency Response CH INPUT 1-11/12
MAIN OUT, MONITOR OUT,
EFFECT OUT, REC OUT
10 k
CH1-4 MIC/LINE: MIC
20 Hz-20 kHz, 0 dB
@ 1 kHz
–3.0 0.0 1.0
dB
SPEAKERS OUT 4 –3.0 0.0 1.0
Maximum Voltage
Gain@ 1 kHz
CH 1-4 INPUT B,
CH 5/6-11/12 MIC
MAIN OUT, MONITOR OUT 10 k
Rs=150 CH1-4
MIC/LINE:MIC
65 dB
Gain Error @ 1 kHz
It measures in each CH unit.
CH 1-4 INPUT B,
CH 5/6-11/12 MIC
MAIN OUT
10 k
Input level:–60 dBu
CH1-4 MIC/LINE:MIC
2.0 4.0 6.0
dBuMONITOR OUT
Input level:–60 dBu
CH1-4 MIC/LINE:MIC
2.0 4.0 6.0
EFFECT OUT
Input level:–60 dBu
CH1-4 MIC/LINE:MIC
–8.0 –6.0 –4.0
REC OUT
Input level:–60 dBu
CH1-4 MIC/LINE:MIC
–12.0 –10.0 –8.0 dBV
CH 1-4 INPUT A MAIN OUT
Input level:–50 dBu
MIC/LINE:MIC
2.0 4.0 6.0
dBu
CH 5/6-7/8 LINE
(Phone)
MAIN OUT Input level:–20 dBu 2.0 4.0 6.0
CH 9/10-11/12 LINE
(Pin)
MAIN OUT Input level:–20 dBu 2.0 4.0 6.0
Total Harmonic Distor-
tion
It measures in each CH unit.
(THD+N)
CH INPUT 1-11/12
MAIN OUT, MONITOR OUT,
EFFECT OUT, REC OUT
10 k
+14 dBu @ 20 Hz,
1 kHz, 20 kHz
0.5 %
Hum & Noise
(20 Hz-20 kHz)
It measures in each CH unit.
EIN=Equivalent Input Noise
CH 1-4 INPUT B,
CH 5/6-11/12 MIC
MAIN OUT
10 k
EIN, Rs=150 CH1-4
MIC/LINE:MIC
–115
dBu
CH INPUT 1-11/12
MAIN OUT, MONITOR OUT,
EFFECT OUT
Output Noise
Rs=150 CH1-4
MIC/LINE:MIC
–50
Residual Output Noise
(20 Hz-20 kHz)
MAIN OUT L, R
10 k
Master control at
minimum.
–90
dBuMONITOR OUT –90
SPEAKERS OUT 4 –65
<
=
Input Output Conditions MIN TYP MAX UNIT
Crosstalk @ 1 kHz
It measures in each CH unit.
CH1-4
Adjacent CH inputs –65
dB
MAIN OUT
Input to Output (LEVEL
controls: minimum)
–65
Output MIN TYP MAX UNIT
Phantom Voltage
It measures in each CH unit.
CH 1-4 INPUT B,
CH 5/6-11/12 MIC
No load 14 15 16 V
CH & ST CH Equaliza-
tion
HIGH Turn over /roll-off frequency of
shelving :3dB below maximum
variable level.
±15dB maximum
10 k (shelving)
HzMID 2.5 k (peaking)
LOW 100 (shelving)
Internal Digital Effect
16 programs
Parameter control
FOOT SW ON/OFF
Level Meters
2 × 5-points LED level meter [MAIN(L,R)], 5-points LED level meter [MONITOR]
+6, +3, 0, –5, –10 [dB]
FCL Sensitivity Input signal level –75dBu: LED on, CH1-4 MIC/LINE:MIC B Input, CH 5/6-11/12 MIC Input
Protection
Power Amplifier
POWER switch on/off mute
DC-fault :power supply shutdown /manual reset
Thermal /heatsink temp 90˚C:output mute /auto reset
Vl limiter /RL 2
Clip limiter /THD 1 %, Indicator × 2
Power Supply Thermal /heatsink temp 100˚C :power supply shutdown /manual reset
>
=
>
=
<
=
>
=
>
=
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha emx212s 8 kanaals powermixer at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha emx212s 8 kanaals powermixer in the language / languages: English as an attachment in your email.

The manual is 3,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info