590158
195
Zoom out
Zoom in
Previous page
1/200
Next page
MIDI Data Format
A-38
Effect Parameter List
No Parameter Range Value See
Table
Con-
trol
HALL1, HALL2, ROOM 1, 2, 3, STAGE 1, 2, PLATE
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0~63 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6
7
8
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11 Rev Delay 0~63 0-63 table#5
12 Density 0~3 0-3
13 Er/Rev Balance E63>R ~ E=R ~ E>R63 1-127
14
15 Feedback Level -63~+63 1-127
16
WHITE ROOM, TUNNEL, BASEMENT
1 Reverb Time 0.3~30.0s 0-69 table#4
2 Diffusion 0~10 0-10
3 Initial Delay 0~63 0-63 table#5
4 HPF Cutoff Thru~8.0kHz 0-52 table#3
5 LPF Cutoff 1.0k~Thru 34-60 table#3
6 Width 0.5~10.2m 0-37 table#11
7 Height 0.5~20.2m 0-73 table#11
8 Depth 0.5~30.2m 0-104 table#11
9 Wall Vary 0~30 0-30
10 Dry/Wet D63>W~D=W~D<W63 1-127
11 Rev Delay 0~63 0-63 table#5
12 Density 0~3 0-3
13 Er/Rev Balance E63>R~E=R~E>R63 1-127
14
15 Feedback Level -63~+63 1-127
16
DELAY L, C, R
1 Lch Delay 0.1~715.0ms 1-7150
2 Rch Delay 0.1~715.0ms 1-7150
3 Cch Delay 0.1~715.0ms 1-7150
4 Feedback Delay 0.1~715.0ms 1-7150
5 Feedback Level -63~+63 1-127
6 Cch Level 0~127 0-127
7 High Damp 0.1~1.0 1-10
8
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11
12
13
EQ Low Frequency
50Hz~2.0kHz 8-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15
EQ High Frequency
500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
DELAY L, R
1 Lch Delay 0.1~715.0ms 1-7150
2 Rch Delay 0.1~715.0ms 1-7150
3 Feedback Delay1 0.1~715.0ms 1-7150
4 Feedback Delay2 0.1~715.0ms 1-7150
5 Feedback Level -63~+63 1-127
6 High Damp 0.1~1.0 1-10
7
8
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11
12
13
EQ Low Frequency
50Hz~2.0kHz 8-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15
EQ High Frequency
500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
ECHO
1 Lch Delay1 0.1~355.0ms 1-3350
2
Lch Feedback Level
-63~+63 1-127
3 Rch Delay1 0.1~355.0ms 1-3550
4
Rch Feedback Level
-63~+63 1-127
5 High Damp 0.1~1.0 1-10
6 Lch Delay2 0.1~355.0ms 1-3550
7 Rch Delay2 0.1~355.0ms 1-3550
8 Delay2 Level 0~127 0-127
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11
12
13
EQ Low Frequency
50Hz~2.0kHz 8-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15
EQ High Frequency
500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
CROSS DELAY
1 L->R Delay 0.1~355.0ms 1-3550
2 R->L Delay 0.1~355.0ms 1-3550
3 Feedback Level -63~+63 1-127
4 Input Select L, R, L&R 0-2
5 High Damp 0.1~1.0 1-10
6
7
8
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11
12
13
EQ Low Frequency
50Hz~2.0kHz 8-40 table#3
14 EQ Low Gain -12~+12dB 52-76
15
EQ High Frequency
500Hz~16.0kHz 28-58 table#3
16 EQ High Gain -12~+12dB 52-76
EARLY REF1, EARLY REF2
1 Type
S-H, L-H, Rdm, Rvs, Plt, Spr
0-5
2 Room Size 0.1~7.0 0-44 table#6
3 Diffusion 0~10 0-10
4 Initial Delay 0~63 0-63 table#5
5 Feedback Level -63~+63 1-127
6 HPF Cutoff Thru~8.0kHz 0-52
7 LPF Cutoff 1.0k~Thru 34-60
8
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11 Liveness 0~10 0-10
12 Density 0~3 0-3
13 High Damp 0.1~1.0 1-10
14
15
16
GATE REVERB, REVERSE GATE
1 Type TypeA, TypeB 0-1
2 Room Size 0.1~7.0 0-44 table#6
3 Diffusion 0~10 0-10
4 Initial Delay 0~63 0-63 table#5
5 Feedback Level -63~+63 1-127
6 HPF Cutoff Thru~8.0kHz 0-52
7 LPF Cutoff 1.0k~Thru 34-60
8
9
10 Dry/Wet D63>W~D=W~D<W63 1-127
11 Liveness 0~10 0-10
12 Density 0~3 0-3
13 High Damp 0.1~1.0 1-10
14
15
16
No Parameter Range Value See
Table
Con-
trol
: Can be controlled by AC1 (Assignable Controller 1)
No.* : These numbers correspond to the Parameter Suffix numbers in <Table 1-3>
See Table** : Refer to “Effect Data Assign Table”
195


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha DC7E3PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha DC7E3PRO in the language / languages: English, Spanish as an attachment in your email.

The manual is 4,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha DC7E3PRO

Yamaha DC7E3PRO User Manual - English - 207 pages

Yamaha DC7E3PRO User Manual - English - 16 pages

Yamaha DC7E3PRO User Manual - English - 5 pages

Yamaha DC7E3PRO User Manual - English - 36 pages

Yamaha DC7E3PRO Quick start guide - English - 10 pages

Yamaha DC7E3PRO User Manual - German - 16 pages

Yamaha DC7E3PRO User Manual - French - 16 pages

Yamaha DC7E3PRO Quick start guide - French - 10 pages

Yamaha DC7E3PRO User Manual - French - 200 pages

Yamaha DC7E3PRO User Manual - Spanish - 207 pages

Yamaha DC7E3PRO User Manual - Spanish - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info