593642
18
Zoom out
Zoom in
Previous page
1/68
Next page
CVP-109/107/105/103/700
18
MIDI Data Format
HARMONIC CONTENT applies adjustment to the resonance value that
is set by the voice. This parameter specifies relative change with the
value of 64 producing 0 adjustment. As values get higher the sound
becomes increasingly eccentric. Note that for some voices the effective
parameter range is narrower than the legal parameter range.
RELEASE TIME applies adjustment to the envelope release time set by
the voice. This parameter specifies relative change with the value of 64
producing 0 adjustment.
ATTACK TIME applies adjustment to the envelope attack time set by the
voice. This parameter specifies relative change with the value of 64
producing 0 adjustment.
BRIGHTNESS applies adjustment to the cut-off frequency set by the
voice. This parameter specifies relative change with the value of 64
producing 0 adjustment. Lower voices produce a softer sound. For some
voices the effective parameter range is narrower than the legal
parameter range.
(3-2) CHANNEL MODE MESSAGES
STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
CONTROL NUMBER 0ccccccc c = CONTROL NUMBER
CONTROL VALUE 0vvvvvvv v = DATA VALUE
(3-2-1) ALL SOUND OFF (Receive only)
(CONTROL NUMBER = 78H , DATA VALUE = 0)
Switches off all sound from the channel. Reset Note On and Hold On conditions established
by Channel Messages.
(3-2-2) RESET ALL CONTROLLERS (Receive only)
(CONTROL NUMBER = 79H , DATA VALUE = 0)
Resets controllers as follows.
PITCH BEND CHANGE 0 (Center)
AFTER TOUCH 0 (min.)
MODULATION 0 (min.)
EXPRESSION 127 (max.)
SUSTAIN 0 (off)
SOSTENUTO 0 (off)
SOFT PEDAL 0 (off)
NRPN Sets number to null. (Internal data remains unchanged)
RPN Sets number to null. (Internal data remains unchanged)
PORTAMENT CONTROL Resets portamento source note number
PORTAMENTO 0 (off)
(3-2-3) ALL NOTES OFF (Receive only)
(CONTROL NUMBER = 7BH , DATA VALUE = 0)
Switches off all of the channel’s “on” notes. However, any notes being held by SUSTAIN or
SOSTENUTO continue to sound until SUSTAIN/SOSTENUTO goes off.
(3-2-4)
OMNI OFF (Receive only) (CONTROL NUMBER = 7CH , DATA VALUE = 0)
Same processing as for All Notes Off.
(3-2-5) OMNI ON (Receive only)
(CONTROL NUMBER = 7DH , DATA VALUE = 0)
Same processing as for All Notes Off. Omni On is not executed.
(3-2-6) MONO (Receive only)
(CONTROL NUMBER = 7EH , DATA VALUE = 0)
Same processing as for All Notes Off. If the 3rd byte is in a range of 0-16 the corresponding
channel will be changed to Mode 4 (m=1).
(3-2-7) POLY (Receive only) (CONTROL NUMBER = 7FH , DATA VALUE = 0)
Same processing as for All Sounds Off and the corresponding channel will be changed to
Mode 3.
(3-3) REGISTERED PARAMETER NUMBER(RPN)
STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
RPN LSB 01100100(64H)
RPN LSB NUMBER 0ppppppp p = RPN LSB (refer to the list below)
RPN MSB 01100101(65H)
RPN MSB NUMBER 0qqqqqqq q = RPN MSB (refer to the list below)
DATA ENTRY MSB 00000110(06H)
DATA VALUE 0mmmmmmm m = Data Value
DATA ENTRY LSB 00100110(26H)
DATA VALUE 0lllllll l = Data Value
First appoints the parameter for RPN MSB/LSB, then sets the parameter value for data entry
MSB/LSB.
RPN D.ENTRY
LSB MSB MSB LSB PARAMETER NAME DATA RANGE
00H 00H mmH
PITCH BEND SENSITIVITY
00H-18H (0 - 24 semitones)
01H 00H mmH llH FINE TUNE
{mmH,llH} = {00H,00H}-{40H,00H}-{7FH,7FH}
(-8192*100/8192) - 0 - (+8192*100/8192)
02H 00H mmH COARSE TUNE
28H - 40H - 58H (-24 - 0 - +24 semitones)
7FH 7FH NULL Clears the current RPN number setting.
Does not change the internal parameter settings.
(3-4) NON-REGISTERED PARAMETER NUMBER(NRPN) (Receive only)
STATUS 1011nnnn(BnH) n = 0 - 15 VOICE CHANNEL NUMBER
NRPN LSB 01100010(62H)
NRPN LSB NUMBER 0ppppppp p = NRPN LSB (refer to the list below)
NRPN MSB 01100011(63H)
NRPN MSB NUMBER 0qqqqqqq q = NRPN MSB (refer to the list below)
DATA ENTRY MSB 00000110(06H)
DATA VALUE 0mmmmmmm m = Data Value
First appoints the parameter for NRPN MSB/LSB, then sets the parameter value for data entry
MSB/LSB.
NRPN D.ENTRY
MSB LSB MSB LSB PARAMETER NAMEDATA RANGE
01H 08H mmH VIBRATO RATE
00H - 40H - 7FH (-64 - 0 - +63)
01H 09H mmH VIBRATO DEPTH
00H - 40H - 7FH (-64 - 0 - +63)
01H 0AH mmH VIBRATO DELAY
00H - 40H - 7FH (-64 - 0 - +63)
01H 20H mmH
FILTER CUTOFF FREQUENCY
00H - 40H - 7FH (-64 - 0 - +63)
01H 21H mmH FILTER RESONANCE
00H - 40H - 7FH (-64 - 0 - +63)
01H 30H mmH
EQ BASS (CVP-109/107/700)
00H - 40H - 7FH (-64 - 0 - +63)
01H 31H mmH
EQ TREBLE
(CVP-109/107/700) 00H - 40H - 7FH (-64 - 0 - +63)
01H 34H mmH
EQ BASS FREQ.
(CVP-109/107/700)
00H - 40H - 7FH (-64 - 0 - +63)
01H 35H mmH
EQ TREBLE FREQ.
(CVP-109/107/700)
00H - 40H - 7FH (-64 - 0 - +63)
01H 63H mmH EG ATTACK TIME
00H - 40H - 7FH (-64 - 0 - +63)
01H 64H mmH EG DECAY TIME
00H - 40H - 7FH (-64 - 0 - +63)
01H 66H mmH EG RELEASE
00H - 40H - 7FH (-64 - 0 - +63)
14H rrH mmH
DRUM FILTER CUTOFF FREQ. 00H - 40H - 7FH (-64 - 0 - +63)
15H rrH mmH
DRUM FILTER RESONANCE
00H - 40H - 7FH (-64 - 0 - +63)
16H rrH mmH DRUM AEG ATTACK RATE
00H - 40H - 7FH (-64 - 0 - +63)
17H rrH mmH DRUM AEG DECAY RATE
00H - 40H - 7FH (-64 - 0 - +63)
18H rrH mmH DRUM PITCH COARSE
00H - 40H - 7FH (-64 - 0 - +63)
19H rrH mmH DRUM PITCH FINE
00H - 40H - 7FH (-64 - 0 - +63)
1AH rrH mmH DRUM LEVEL
00H - 7FH (0 - max.)
1CH rrH mmH DRUM PANPOT
00H ,01H - 40H - 7FH
(random,left - center - right)
1DH rrH mmH
DRUM REVERB SEND LEVEL
00H - 7FH (0 - max.)
1EH rrH mmH
DRUM CHORUS SEND LEVEL
00H - 7FH (0 - max.)
1FH rrH mmH
DRUM VARIATION SEND LEVEL 00H - 7FH (0 - max.)
The MSB 14H-1FH (for drums) message is received when multi-part parameters PART
MODE = DRUMS1...2.
rrH : drum instrument note number
(3-5) SYSTEM REALTIME MESSAGES
(3-5-1) MIDI CLOCK
STATUS 11111000 (F8H)
Transmission: 96 clocks per measure are transmitted.
Reception: If the instrument’s clock is set to external, after FAH is received from the external
device the instrument’s clock will sync with the 96 beats per measure received from the external
device.
Decides whether the internal clock, or Timing Clocks received via the MIDI IN will be used.
(3-5-2) START
STATUS 11111010 (FAH)
Transmission: Transmitted when instrument’s Rhythm or Song playback is started.
Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will start.
(3-5-3) STOP
STATUS 11111100 (FCH)
Transmission: Transmitted when instrument’s Rhythm or Song playback is stopped.
Reception: Depending upon the condition, Rhythm, Song Playback, or Song Rec will stop.
(3-5-4) ACTIVE SENSING
STATUS 11111110 (FEH)
Transmission: Transmitted approximately once every 200msec.
Reception: Sensing is started once this Code is received. If Status or Data is not received within
400ms, the MIDI Receive Buffer will be cleared, and all notes, including those being sustained,
will be cut OFF. Also, all control values will be reset to their factory defaults.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha CVP-105 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha CVP-105 in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha CVP-105

Yamaha CVP-105 User Manual - English - 235 pages

Yamaha CVP-105 User Manual - German - 68 pages

Yamaha CVP-105 User Manual - German - 235 pages

Yamaha CVP-105 User Manual - Dutch - 292 pages

Yamaha CVP-105 User Manual - French - 68 pages

Yamaha CVP-105 User Manual - French - 235 pages

Yamaha CVP-105 User Manual - Italian - 246 pages

Yamaha CVP-105 User Manual - Portuguese - 150 pages

Yamaha CVP-105 User Manual - Swedish - 247 pages

Yamaha CVP-105 User Manual - Spanish - 68 pages

Yamaha CVP-105 User Manual - Spanish - 235 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info