MIDI Data Format
126
Appendix
28 1 00...7F Step Seq Gate Time LSB 3 *1 94%(3C)
29 1 00...7F Step Seq Gate Time LSB 4 *1 94%(3C)
2A 1 00...7F Step Seq Gate Time LSB 5 *1 94%(3C)
2B 1 00...7F Step Seq Gate Time LSB 6 *1 94%(3C)
2C 1 00...7F Step Seq Gate Time LSB 7 *1 94%(3C)
2D 1 00...7F Step Seq Gate Time LSB 8 *1 94%(3C)
2E 1 00...7F Step Seq Gate Time LSB 9 *1 94%(3C)
2F 1 00...7F Step Seq Gate Time LSB 10 *1 94%(3C)
30 1 00...7F Step Seq Gate Time LSB 11 *1 94%(3C)
31 1 00...7F Step Seq Gate Time LSB 12 *1 94%(3C)
32 1 00...7F Step Seq Gate Time LSB 13 *1 94%(3C)
33 1 00...7F Step Seq Gate Time LSB 14 *1 94%(3C)
34 1 00...7F Step Seq Gate Time LSB 15 *1 94%(3C)
35 1 00...7F Step Seq Gate Time LSB 16 *1 94%(3C)
36 1 NOT USED --
37 1 NOT USED --
38 1 NOT USED --
39 1 NOT USED --
3A 1 NOT USED --
3B 1 NOT USED --
3C 1 NOT USED --
3D 1 NOT USED --
3E 1 NOT USED --
3F 1 NOT USED --
40 1 NOT USED --
41 1 NOT USED --
42 1 NOT USED --
43 1 NOT USED --
44 1 NOT USED --
45 1 NOT USED --
46 1 00...07 Step Seq Gate Time MSB 1 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
47 1 00...07 Step Seq Gate Time MSB 2 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
48 1 00...07 Step Seq Gate Time MSB 3 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
49 1 00...07 Step Seq Gate Time MSB 4 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
4A 1 00...07 Step Seq Gate Time MSB 5 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
4B 1 00...07 Step Seq Gate Time MSB 6 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
4C 1 00...07 Step Seq Gate Time MSB 7 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
4D 1 00...07 Step Seq Gate Time MSB 8 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
4E 1 00...07 Step Seq Gate Time MSB 9 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
4F 1 00...07 Step Seq Gate Time MSB 10 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
50 1 00...07 Step Seq Gate Time MSB 11 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
51 1 00...07 Step Seq Gate Time MSB 12 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
52 1 00...07 Step Seq Gate Time MSB 13 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
53 1 00...07 Step Seq Gate Time MSB 14 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
54 1 00...07 Step Seq Gate Time MSB 15 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
55 1 00...07 Step Seq Gate Time MSB 16 1%(0)...100%(40)...200%(7F)...1600%(3FF) *1,2 0
56 1 00...01 Step Seq Mute 1 MuteOFF(0),MuteON(1) MuteOFF(0)
57 1 00...01 Step Seq Mute 2 MuteOFF(0),MuteON(1) MuteOFF(0)
58 1 00...01 Step Seq Mute 3 MuteOFF(0),MuteON(1) MuteOFF(0)
59 1 00...01 Step Seq Mute 4 MuteOFF(0),MuteON(1) MuteOFF(0)
5A 1 00...01 Step Seq Mute 5 MuteOFF(0),MuteON(1) MuteOFF(0)
5B 1 00...01 Step Seq Mute 6 MuteOFF(0),MuteON(1) MuteOFF(0)
5C 1 00...01 Step Seq Mute 7 MuteOFF(0),MuteON(1) MuteOFF(0)
5D 1 00...01 Step Seq Mute 8 MuteOFF(0),MuteON(1) MuteOFF(0)
5E 1 00...01 Step Seq Mute 9 MuteOFF(0),MuteON(1) MuteOFF(0)
5F 1 00...01 Step Seq Mute 10 MuteOFF(0),MuteON(1) MuteOFF(0)
60 1 00...01 Step Seq Mute 11 MuteOFF(0),MuteON(1) MuteOFF(0)
61 1 00...01 Step Seq Mute 12 MuteOFF(0),MuteON(1) MuteOFF(0)
62 1 00...01 Step Seq Mute 13 MuteOFF(0),MuteON(1) MuteOFF(0)
63 1 00...01 Step Seq Mute 14 MuteOFF(0),MuteON(1) MuteOFF(0)
64 1 00...01 Step Seq Mute 15 MuteOFF(0),MuteON(1) MuteOFF(0)
65 1 00...01 Step Seq Mute 16 MuteOFF(0),MuteON(1) MuteOFF(0)
TOTAL SIZE 66
*1 : MSB bit 2-0 -> bit 9-7
LSB bit 6 -0 -> bit 6-0
*2 : This should be transmitted after sending Step Seq Gate Time LSB n.
<1-8>
MIDI Bulk Dump Parameter table ( User Pattern Voice )
Address Size Data Prameter Name Description Default
(H) (H) (H)
20 mm 00 1 20...7F Voice Name 1 Ascii Code I
01 1 20...7F Voice Name 2 Ascii Code n
02 1 20...7F Voice Name 3 Ascii Code I
03 1 20...7F Voice Name 4 Ascii Code t
04 1 20...7F Voice Name 5 Ascii Code
05 1 20...7F Voice Name 6 Ascii Code P
06 1 20...7F Voice Name 7 Ascii Code t
07 1 20...7F Voice Name 8 Ascii Code n
08 1 20...7F Voice Name 9 Ascii Code
09 1 20...7F Voice Name 10 Ascii Code
0a 1 00...16 Voice Category --,Pf...Wv --
0b 1 NOT USED (AN1x : Scene Select) Scene1(1):fixed 1(scene1)
0c 1 00...01 Unison Sw. (AN1x : Layer Mode) off(0),on(1) 00(off)
0d 1 NOT USED --
0e 1 NOT USED --
0f 1 01...20 Unison Detune 1...32 6
10 2 27...F0 Common Tempo 20(14h) ... 40(28h) ... 240(F0h) ... 300(12Ch) 8C(140)
12 1 NOT USED --
13 1 NOT USED --
14 1 NOT USED --
15 1 NOT USED --
16 1 NOT USED --
126


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha AN200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha AN200 in the language / languages: English as an attachment in your email.

The manual is 6,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha AN200

Yamaha AN200 User Manual - German - 147 pages

Yamaha AN200 User Manual - Dutch - 120 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info