● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● A5000/A4000 • Appendix 279
Table1 Bulk Dump
Each data byte is divided into the upper and lower 4 bits and received/transmitted as 2 bytes of MIDI
data.
1.1 Voice Parameter Bulk Dump
1.1.1 Program Bulk Dump 408+56*(number of samples)byte
(*1) Number of samples/sample banks for which ToPgm is on.
(*2) -2:off, -1:AUDITION, 0-15:A01-16, 16:basic receive channel, 17-32:B01-16(A5000 only)
(*3) -1:all
(*4) Refer to *8 of “2.1.1 Program Parameters”.
1.1.2 Sample Bank Bulk Dump 312+20*(number of samples)byte
(*1) b31(MSB) — b0(LSB):P2=31 — 0
(*2) b31(MSB) — b0(LSB):P2=63 — 32
(*3) b31(MSB) — b0(LSB):P2=95 — 64
P2, above, applies to P2 = 0-88 of the “Sample Parameter” block of “2.1.4 Parameter Block.
1.1.3 Sample Bulk Dump 336byte
(*1) No assignment when the first byte is $00.
1.1.4 Wave Data Bulk Dump 72+2*(wave data word size)byte
1.1.5 Sequence Bulk Dump 72+(sequence data byte size)byte
1.1.6 Object List Bulk Dump 17*(number of all objects)byte
(*1) sample:16, sample bank:17, sequence:19, program:20"
1.1.7 Parameter Block
[Common] 64byte
(*1) sample:16, sample bank:17, sequence:19, program:20
(*2) wave data word size for wave data bulk dump,
sequence data word size for sequence bulk dump,
0 in all other cases.
data byte
Item Type Description 1st 2nd 3rd 4th
offset decimal Address offset
data
size
UC 1 byte (unsigned 8 bit) b7-b0
SC
1 byte (signed 8 bit, 2’s com-
plement)
sign,b6-b0
US 2 byte (unsigned 16 bit) b15-b8 b7-b0
SS
2 byte (signed 16 bit, 2’s
complement)
sign,b14-b8 b7-b0
UL 4 byte (unsigned 32 bit) b31-b24 b23-16 b15-b8 b7-b0
SL
4 byte (signed 32 bit, 2’s
complement)
sign,b30-b24 b23-16 b15-b8 b7-b0
*n n bytes of each data type
value
c
All displayable ASCII codes
except ¥
b
Bitmap type
Refer to the name column for
bit position
Unused or internal use only
(0 not appropriate)
name [ ]
Parameter block
Refer to each parameter
block for details
original data byte b7,b6,b5,b4,b3,b2,b1,b0
MIDI
data
1st byte 0,0,0,0,b7,b6,b5,b4
2nd byte 0,0,0,0,b3,b2,b1,b0
offset data size value name
0000 64byte [Common]
0064 UC*8 c program name
0072 UC b b0:AD in on, b2-1:AD in source,
b5-3:effect1-3 connection, b7-6:program LFO sync
0073 UC b b2-0:program LFO cycle, b5-3:program LFO wave,
b7-6:program LFO initial phase
0074 US b b0:MIDI channelA01 controller reset...
b15:MIDI channelA16 controller reset
0076 US b b0:MIDI channelA01 note on normal/toggle...
b15:MIDI channelA16 note on normal/toggle
0078 SC ±63 AD in (L) pan
0079 UC reserved
0080 UC reserved
0081 UC reserved
0082 UC reserved
0083 UC 0-127 program level
0084 SC reserved
0085 SC reserved
0086 SC ±127 program transpose
0087 SC -2,-1,0-32 program LFO reset MIDI channel (*2)
0088 UC 0-3 program portamento type
0089 UC 0-127 program portamento rate
0090 UC 0-127 program portamento time
0091 UC 0-127 S/H speed
0092 UC 25-250 program LFO tempo
0093 SC -1,0-127 program LFO reset note (*2)
0094 US 0-999 number of assigned samples (*1)
0096 120byte [Effect Parameter]*3 (effect1-3)
0216 16byte reserved
0232 120byte [Effect Parameter]*3 (effect4-6) (A5000 only)
0352 16byte [Control]*4 (program control1-4)
0368 US b b0:MIDI channel B01 controller reset...
b15:MIDI channel B16 controller reset (A5000 only)
0370 US b b0:MIDI channel B01 note on normal/toggle...
b15:MIDI channel B16 note on normal/toggle
(A5000 only)
0372 UC b b2-0:effect4-6 connection (A5000 only)
0373 UC 0-12 AD in (L) output1 (*4)
0374 UC 0-127 AD in (L) level1
0375 UC 0-12 AD in (L) output2 (*4)
0376 UC 0-127 AD in (L) level2
0377 SC ±63 AD in R pan
0378 UC 0-12 AD in R output1 (*4)
0379 UC 0-127 AD in R level1
0380 UC 0-12 AD in R output2 (*4)
0381 UC 0-127 AD in R level2
0382 UC*16 0-127 program LFO step wave value1-16
0398 UC b b2-0:total steps of step wave, b4-3:step wave slope
0399 9byte reserved
0408 56*n byte [Easy Edit Parameter]*(number of samples)
offset data size value name
0000 64byte [Common]
0064 224byte [Sample Parameter]
0288 UL b sample bank value enable (*1)
0292 UL b sample bank value enable (*2)
0296 UL b sample bank value enable (*3)
0300 UL reserved
0304 UC 0-127 number of assigned samples
0305 UC*7 reserved
0312 20*n byte [Sample Bank Member]*(number of samples)
offset data size value name
0000 64byte [Common]
0064 UC*16 c linked wave object name L (*1)
0080 UC*16 c linked wave object name R (*1)
0096 UL*2 reserved
0104 UL*2 reserved
0112 224byte [Sample Parameter]
offset data size value name
0000 64byte [Common]
0064 SS reserved
0066 US reserved
0068 US reserved
0070 US reserved
0072 US*n wave data (n='size' in [Common])
offset data size value name
0000 64byte [Common]
0064 US 50-250 original tempo
0066 US reserved
0068 US reserved
0070 US reserved
0072 UC*n sequence data (n='size' in [Common])
offset data size value name
0000 UC object type (*1)
0001 UC*16 c name
:
Repeat for all objects saved in memory, from obj type to name.
:
offset data size value name
0000 UC object type (*1)
0001 UC reserved
0002 UC*16 c name
0018 UC*2 reserved
0020 UL size (*2)
0024 UC*16 reserved
0040 UC*16 reserved
0056 UC reserved
0057 UC*3 reserved
0060 UL reserved
279


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha A4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha A4000 in the language / languages: English as an attachment in your email.

The manual is 10,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha A4000

Yamaha A4000 User Manual - German - 296 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info