MIDI Data Format
278 Appendix • A5000/A4000 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
5.3.1. Parameter change (object select)
0 01110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000000 $00
5 0ccccccc
object name(ASCII 16byte)
20 0ccccccc
22 0ttttttt object type
21 11110111 $F7
Functions as an object select message.
This message specifies the object.
object name is a 16-character name for each object. Program object names are the program num-
ber of each program (example: “001 “).
The object type is shown in the following table.
t Data type
20($14) Program
17($11) Sample Bank
16($10) Sample
2($02) Wave data
19($13) Sequence
5.3.2. Parameter change (object edit)
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000001 $01
5 0ppppppp
parameter number P1-P6(6byte)
10 0ppppppp
11 0ddddddd
data
0ddddddd
11110111 $F7
Changes the value of the object parameter specified by object select.
The parameters comply with P1, P2 — P6 in chart 2.
The number of data bytes depends on the parameter. The data section is divided into byte 1, which
is the upper nibble, and byte 2, which is the lower nibble. See chart 2 for details.
5.3.3. Parameter change (system parameter)
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000010 $02
5 0ppppppp
parameter number P1-P6 (6byte)
10 0ppppppp
11 0ddddddd
data
0ddddddd
01110111 $F7
This message is a parameter change for system parameters.
The parameters comply with P1, P2 — P6 in chart 2.
The number of data bytes depends on the parameter. The data section is divided into byte 1, which
is the upper nibble, and byte 2, which is the lower nibble. See chart 2 for details.
5.3.4. Parameter change (switch remote)
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000011 $03
5 0ppppppp switch number
6 00000000 $00
10 00000000 $00
11 0ddddddd data
27 11110111 $F7
This message performs remote control of switches.
For the switch numbers, refer to table 2.
With the exception of switch numbers 123-127, data of $00-$3F turns the switch off, and data of
$40-$7F turns the switch on.
For switch numbers 123-127 (knob encoders), a value of 64 less than the data specifies the num-
ber of pulses which correspond to rotation (30 pulses per rotation). Positive numbers are rotation
toward the right, and negative numbers are rotation toward the left.
This message is received only.
5.3.5. Parameter request (object)
0 11110000 $F0
1 01000011 $43
2 0011nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000001 $01
5 0ppppppp
parameter number P1-P6 (6byte)
10 0ppppppp
11 11110111 $F7
This message requests transmission of the parameter of the specified object as a parameter
change.
The parameters comply with P1, P2 — P6 in chart 2.
This message is received only.
5.3.6. Parameter request (system parameter)
0 11110000 $F0
1 01000011 $43
2 0011nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000010 $02
5 0ppppppp
parameter number P1-P6 (6byte)
10 0ppppppp
11 11110111 $F7
This message requests transmission of a system parameter as a parameter change.
The parameters comply with P1, P2 — P6 in chart 2.
This message is received only.
5.3.7. Object Link Change
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000100 $04
5 0ccccccc
upper object name(ASCII 16byte)
20 0ccccccc
21 0ttttttt upper object type
22 0ccccccc
lower object name(ASCII 16byte)
37 0ccccccc
38 0ttttttt lower object type
39 0ddddddd data (0:link off, 1:link on)
40 11110111 $F7
Changes the link condition between specified objects (between Program and Sample/Sample
Bank Program is upper, and between Sample Bank and Sample is upper). Nothing occurs when an
object is selected which is not changeable, or which requires samples to be copied.
object name is a 16-character name for each object. Program object names are the program num-
ber of each program (example: “001 “).
The object type is shown in the following table.
t Data type
20($14) Program
17($11) Sample Bank
16($10) Sample
5.3.8. Object Link Request
0 11110000 $F0
1 01000011 $43
2 0011nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000100 $04
5 0ccccccc
upper object name(ASCII 16byte)
20 0ccccccc
21 0ttttttt upper object type
22 0ccccccc
lower object name(ASCII 16byte)
37 0ccccccc
38 0ttttttt lower object type
39 0ddddddd data (0:link off, 1:link on)
40 11110111 $F7
When received the link condition between specified objects (between Program and Sample/Sam-
ple Bank Program is upper, and between Sample Bank and Sample is upper) is transmitted in
object link change format. This message is receive only.
The object type is shown in the following table.
t Data type
20($14) Program
17($11) Sample Bank
16($10) Sample
278


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha A4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha A4000 in the language / languages: English as an attachment in your email.

The manual is 10,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha A4000

Yamaha A4000 User Manual - German - 296 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info