MIDI-dataformat 315
01V96—Handleiding
2.8.2.24 Channel library bulk dump request format
The second and third bytes of the DATA NAME indicate the bank number. (See
above)
2.8.2.25 Input patch library bulk dump format
The second and third bytes of the DATA NAME indicate the bank number.
0:Library no.0 – 32:Library no.32, 256:current input patch data, 8192:UNDO
For reception by the 01V96, only the user area is valid. (1-32, 256, 8192)
2.8.2.26 Input patch library bulk dump request format
The second and third bytes of the DATA NAME indicate the bank number. (See
above)
2.8.2.27 Output patch library bulk dump format
The second and third bytes of the DATA NAME indicate the bank number.
0:Library no.0 – 32:Library no.32, 256:current output patch data, 8192:UNDO
For reception by the 01V96, only the user area is valid. (1-32, 256)
2.8.2.28 Output patch library bulk dump request format
The second and third bytes of the DATA NAME indicate the bank number. (See
above)
00111001 39
‘9’
00110011 33
‘3’
DATA NAME 01001000 48
‘H’
0mmmmmmm mh
0-128(Channel Library no.0-128),
0mmmmmmm ml
256-(Current data)
BLOCK INFO. 0ttttttt tt
total block number(minimum number is 0)
0bbbbbbb bb
current block number(0-total block number)
DATA 0ddddddd ds
Channel Library data of block[bb]
::
0ddddddd de
CHECK SUM 0eeeeeee ee
ee=(Invert(‘L’+…+de)+1)&0x7F
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS 0010nnnn 2n
n=0-15 (Device number=MIDI Channel)
FORMAT No. 01111110 7E
Universal bulk dump
01001100 4C
‘L
01001101 4D
‘M’
00100000 20
‘ ’
00100000 20
‘ ’
00111000 38
‘8’
01000011 43
‘C’
00111001 39
‘9’
00110011 33
‘3’
DATA NAME 01001000 48
‘H’
0mmmmmmm mh
0-128(Channel Library no.0-128),
0mmmmmmm ml
256-(Current data)
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS 0000nnnn 0n
n=0-15 (Device number=MIDI Channel)
FORMAT No. 01111110 7E
Universal bulk dump
COUNT HIGH 0ccccccc ch
data count = ch * 128 + cl
COUNT LOW 0ccccccc cl
01001100 4C
‘L
01001101 4D
‘M’
00100000 20
‘ ’
00100000 20
‘ ’
00111000 38
‘8’
01000011 43
‘C’
00111001 39
‘9’
00110011 33
‘3’
DATA NAME 01010010 52
‘R’
0mmmmmmm mh
0-32(Input patch Library no.0-32),
0mmmmmmm ml
256(Current data)
BLOCK INFO. 0ttttttt tt
total block number(minimum number is 0)
0bbbbbbb bb
current block number(0-total block number)
DATA 0ddddddd ds
Input patch Library data of block[bb]
::
0ddddddd de
CHECK SUM 0eeeeeee ee
ee=(Invert(‘L’+…+de)+1)&0x7F
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS 0010nnnn 2n
n=0-15 (Device number=MIDI Channel)
FORMAT No. 01111110 7E
Universal bulk dump
01001100 4C
‘L
01001101 4D
‘M’
00100000 20
‘ ’
00100000 20
‘ ’
00111000 38
‘8’
01000011 43
‘C’
00111001 39
‘9’
00110011 33
‘3’
DATA NAME 01010010 52
‘R’
0mmmmmmm mh
0-32(Input patch Library no.0-32),
0mmmmmmm ml
256(Current data)
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS 0000nnnn 0n
n=0-15 (Device number=MIDI Channel)
FORMAT No. 01111110 7E
Universal bulk dump
COUNT HIGH 0ccccccc ch
data count = ch * 128 + cl
COUNT LOW 0ccccccc cl
01001100 4C
‘L
01001101 4D
‘M’
00100000 20
‘ ’
00100000 20
‘ ’
00111000 38
‘8’
01000011 43
‘C’
00111001 39
‘9’
00110011 33
‘3’
DATA NAME 01001111 4F
‘O’
0mmmmmmm mh
0-32(Output patch Library no.0-32),
0mmmmmmm ml
256(Current data)
BLOCK INFO. 0ttttttt tt
total block number(minimum number is 0)
0bbbbbbb bb
current block number(0-total block number)
DATA 0ddddddd ds
Output patch Library data of block[bb]
::
0ddddddd de
CHECK SUM 0eeeeeee ee
ee=(Invert(‘L’+…+de)+1)&0x7F
EOX 11110111 F7
End of exclusive
STATUS 11110000 F0
System exclusive message
ID No. 01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS 0010nnnn 2n
n=0-15 (Device number=MIDI Channel)
FORMAT No. 01111110 7E
Universal bulk dump
01001100 4C
‘L
01001101 4D
‘M’
00100000 20
‘ ’
00100000 20
‘ ’
00111000 38
‘8’
01000011 43
‘C’
00111001 39
‘9’
00110011 33
‘3’
DATA NAME 01001111 4F
‘O’
0mmmmmmm mh
0-32(Output patch Library no.0-32),
0mmmmmmm ml
256(Current data)
EOX 11110111 F7
End of exclusive
315


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yamaha 01V96 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yamaha 01V96 in the language / languages: Dutch as an attachment in your email.

The manual is 6,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Yamaha 01V96

Yamaha 01V96 User Manual - English - 334 pages

Yamaha 01V96 User Manual - German - 334 pages

Yamaha 01V96 User Manual - French - 334 pages

Yamaha 01V96 User Manual - Italian - 333 pages

Yamaha 01V96 User Manual - Spanish - 331 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info