991
OperaTing Manual
Menu MODe
001 AGC FAST DELAY
Function: Sets the AGC-FAST DELAY voltage decay
characteristics.
Available Values: 20 - 4000msec
(
20msec/step
)
Default Setting: 300msec
Description: Sets the AGC voltage decay characteristics
in 20 msec steps after the input signal level
becomes lower than the AGC detection
level and the HOLD time is over.
002 AGC MID DELAY
Function: Sets the AGC-MID DELAY voltage decay
characteristics.
Available Values: 20 - 4000msec
(
20msec/step
)
Default Setting: 700msec
Description: Sets the AGC voltage decay characteristics
in 20 msec steps after the input signal level
becomes lower than the AGC detection
level and the HOLD time is over.
003 AGC SLOW DELAY
Function: Sets the AGC-SLOW DELAY voltage decay
characteristics.
Available Values: 20 - 4000msec
(
20msec/step
)
Default Setting: 3000msec
Description: Sets the AGC voltage decay characteristics
in 20 msec steps after the input signal level
becomes lower than the AGC detection
level and the HOLD time is over.
004 HOME FUNCTION
Function: Selects the information to be displayed on the
HOME screen.
Available Values: SCOPE/FUNCTION
Default Setting: SCOPE
Description: Selects the information to be displayed on
the HOME screen
(
main screen
)
.
SCOPE: Displays the scope screen.
FUNCTION: Displays the function key
screen.
005 MY CALL INDICATION
Function: Sets the display time duration for MY CALL.
Available Values: OFF - 5sec
Default Setting: 1sec
Description: Sets the display time duration for a message
such as the call sign set from MY CALL
when turning on the power.
006 DISPLAY COLOR
Function: Sets the background color of the VFO-A fre-
quency display eld.
Available Values: BLUE/GRAY/GREEN/ORANGE/
PURPLE/RED/SKY BLUE
Default Setting: BLUE
Description: Sets the background color of the VFO-
A frequency display field. The color may
be previewed before the selection is con-
rmed.
007 DIMMER LED
Function: Sets the key LED brightness level.
Available Values: 1 / 2
Default Setting: 2
Description: Sets the brightness level of the LED indi-
cator located above the Main Tuning Dial
knob. The effect of the changes may be
observed as the brightness level is adjusted.
1
” is the darkest.
008 DIMMER TFT
Function: Sets the TFT display brightness level.
Available Values: 0 - 15
Default Setting: 8
Description: Sets the brightness level of the TFT display.
The effect of the changes may be observed
as the brightness level is adjusted. The
higher the setting, the brighter the illumina-
tion becomes.
009 BAR MTR PEAK HOLD
Function: Sets the bar meter peak hold.
Available Values: OFF/0.5/1.0/2.0
(
sec
)
Default Setting: OFF
Description: Sets the time length the maximum value
reading is shown on the meter
(
peak hold
)
.
OFF: Disables the peak hold function.
0.5/1.0/2.0: Holds the maximum value for the
time length that is set.
010 DVS RX OUT LEVEL
Function: Sets the voice memory monitoring level.
Available Values: 0 - 100
Default: 50
Description: You can adjust the voice memory monitor-
ing level. The higher the setting, the higher
the output level becomes.
011 DVS TX OUT LEVEL
Function: Sets the microphone output level for the voice
memory.
Available Values: 0 - 100
Default: 50
Description: The microphone output level may be ad-
justed to the operators own voice and pref-
erence. For example, the output level may
be set differently between the microphone
and the voice memory. The higher the set-
ting, the higher the output level becomes.
126


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-991A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-991A in the language / languages: English as an attachment in your email.

The manual is 36,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info