Page 108 FT-950 OPERATING MANUAL
AGC GROUP
001 AGC FST DLY
Function: Sets the delay time for the AGC FAST mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 300 msec
002 AGC MID DLY
Function: Sets the delay time for the AGC MID mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 700 msec
003 AGC SLW DLY
Function: Sets the delay time for the AGC SLOW mode.
Available Values: 20 ~ 4000 msec (20 msec/step)
Default Setting: 3000 msec
DISPLAY GROUP
004 DISP COLOR
Function: Selects the Display color when the optional Data
Management Unit (DMU-2000) is connected.
Available Values: bL1/bL2/bL3/ub1/ub2
Default Setting: bL1 (COOL BLUE)
bL1: COOL BLUE
bL2: CONTRAST BLUE
bL3: FLASH WHITE
ub1: CONTRAST UMBER
ub2: UMBER
ADVICE:
If the optional DMU-2000 Data Management Unit is not
connected, this adjustment has no effect.
005 DISP DIM VFD
Function: Setting of the display brightness level.
Available Values: 0 ~ 15
Default Setting: 8
006 DISP BAR SEL
Function: Selects one of three parameters to be viewed
on the Tuning Offset Indicator.
Available Values: CLAr/C-tn/u-tn
Default Setting: C-tn
CLAr: Displays relative clarifier offset.
C-tu: Displays relative tuning offset between the incom-
ing signal and transmitted frequency while in CW
operation.
u-tn: Displays the peak position of the optional µ-TUNE
filter.
007 DISP PKH S
Function: Selects the peak hold time of the S-meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
008 DISP PKH PO
Function: Selects the peak hold time of the PO meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
009 DISP PKH ALC
Function: Selects the peak hold time of the ALC meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
010 DISP PKH ID
Function: Selects the peak hold time of the ID meter.
Available Values: OFF/0.5/1.0/2.0 sec
Default Setting: OFF
MENU MODE
110


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-950 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-950 in the language / languages: English as an attachment in your email.

The manual is 6,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info