SSB/AM MODE TRANSMISSION
ADVICE:
ALC meter deflection may be caused by excessive drive
power, but also by reflected power detected in the an-
tenna system. If the impedance presented to the trans-
ceiver is different from 50 Ohms, ALC meter action
may be observed that is not related to the proper set-
ting of the
[
MIC GAIN
]
knob. Therefore, we recom-
mend that you make the
[
MIC GAIN
]
knob adjustments
into a dummy load or antenna system presenting im-
pedance very close to 50 Ohms.
In the SSB mode, you may set the desired power out-
put via the Menu item “111 TGEN TX PWR”. The
adjustment range is between 5 Watts and 100 Watts.
You should always use the minimum power necessary
to maintain reliable communications.
When performing “on air” tests (such as the setup of
microphone gain), be sure to check the frequency be-
fore transmitting, to avoid interference to others who
may already be using the frequency.
Four techniques for exercising Transmit/Receive con-
trol are provided on the FT-950. You may choose the
technique(s) that best suit your operating needs:
Pressing the microphone PTT switch will engage
the transmitter.
The rear panel PTT jack may be connected to a
foot switch or other manual switching device in
order to engage the transmitter.
Pressing the front panel
[
MOX
]
button will lock
the transmitter on. Press the
[
MOX
]
button again
to return to receive.
The VOX (Voice Operated Xmit) circuit will en-
gage the transmitter automatically when you speak
into the microphone. For details of VOX opera-
tion, see page 66.
Adjusting the AM Carrier
[
CLAR/VFO-B
]
Knob
[
MENU
]
Button
[
SELECT
]
Knob
1. Press the
[
MENU
]
button to enter the Menu mode.
2. Rotate the
[
SELECT
]
knob to select Menu item
112 TGEN AM CAR”.
ADVICE:
Press the
[
SELECT
]
knob to toggle the Menu item
display between “112 TGEN” and “AM CAR”.
3. Close the PTT switch. Do not speak into the mi-
crophone. Rotate the
[
CLAR/VFO-B
]
knob to ad-
just the PO meter reading is “25 W”.
4. Press and hold in the
[
MENU
]
button for one sec-
ond to save the new setting and exit to normal op-
eration.
PO Meter
[
CLAR/VFO-B
]
Knob
[
MENU
]
Button
[
SELECT
]
Knob
Multi-Display Window
Adjusting the SSB TX Power Output
1. Press the
[
MENU
]
button to enter the Menu mode.
2. Rotate the
[
SELECT
]
knob to select Menu item
111 TGEN TX PWR”.
ADVICE:
If necessary, press the
[
SELECT
]
knob to toggle
the Menu item display between “111 TGEN” and
TX PWR”.
3. Close the PTT switch, and then rotate the
[
CLAR/
VFO-B
]
knob to adjust the desired power output
on the Multi-Display Window.
ADVICE:
The value (5 -100) displayed in the Multi-Display
window is a relative percentage of the maximum
TX power available in the selected mode. It is not
the true TX output level.
4. Press and hold in the
[
MENU
]
button for one sec-
ond to save the new setting and exit to normal op-
eration.
ADVICE:
The TX Power Output setting cannot be stored in any
of the memory channels.
ADVICE:
The AM TX Power Output setting cannot be stored in
any of the memory channels.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-950 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-950 in the language / languages: English as an attachment in your email.

The manual is 6,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info