Page 119FT-2000D OPERATING MANUAL
034 GEnE TRACK
Function: Sets the VFO Tracking feature.
Available Values: OFF / bAND / FrEq
Default Setting: OFF
OFF: Disables the VFO Tracking feature.
bAND: When you change bands on the Main (VFO-
A) side, the Sub (VFO-B) band’s VFO will
automatically change to be the same as that of
VFO-A.
FrEq: This function is the almost same as “bAND,”
however, furthermore, the Sub band’s (VFO-
B) frequency changes together with the Main
Band’s (VFO-A) frequency when turning the
Main Dial Tuning knob.
035 GEnE TX TOT
Function: Sets the Time-Out Timer countdown time.
Available Values: OFF / 3 / 5 / 10 / 15 / 20 / 30 min
Default Setting: OFF
The Time-Out Timer shuts off the transmitter after con-
tinuous transmission of the programmed time.
036 GEnE TRV SET
Function: Sets the 10’s and 1’s of the MHz digits display
for operation with a transverter.
Available Values: 30 ~ 49 MHz
Default Setting: 44 MHz
The default setting would be used with a 144 MHz
transverter. If you connect a 430 MHz transverter to the
radio, set this menu to “30” (the “100 MHz” digits are
hidden on this radio).
037 GEnE μT DIAL
Function: Selects the μ-TUNE mode.
Available Values: StP1 / StP2 / OFF
Default Setting: StP1
StP1: Activates the μ-TUNE system using
“COARSE” steps of the
[
VRF
]
knob (2 steps/
click) on the 7 MHz and lower amateur bands.
On the 10/14 MHz bands, “FINE”
[
VRF
]
knob
steps (1 step/click) will be used.
StP2: Activates the μ-TUNE system using “FINE”
steps of the
[
VRF
]
knob (1 step/click) on the
14 MHz and lower amateur bands on the Main
band (VFO-A).
OFF: Disables the μ-TUNE system. Activates the
VRF feature on the 14 MHz and lower amateur
bands on the main band (VFO-A).
ADVICE:
If the optional RF μTuning Kit is not connected, this ad-
justment has no effect.
038 GEnE SNB LVL
Function: Adjusts the Sub band (VFO-B) receiver’s IF
Noise Blanker level, when the Noise Blanker is engaged.
Available Values: nAin(MAIN) / 0~100
Default Setting: nAin(MAIN)
When this menu is set to “nAin(MAIN),” you may adjust
the Noise Blanker level using the front panel’s
[
NB
]
knob.
039 GEnE SUB FIL
Function: Defines the Sub band (VFO-B) receivers CW
narrow filter.
Available Values: 1200 / 500 / 300 Hz
Default Setting: 1200 Hz
ADVICE:
This Menu item tells the microprocessor which (if any)
optional filter has been installed.
040 GEnE MIC SCN
Function: Enables/disables scanning access via the
microphone’s
[
UP
]
/
[
DWN
]
keys.
Available Values: On / OFF
Default Setting: On
041 GEnE SCN RSM
Function: Selects the Scan Resume mode.
Available Values: CAr / 5SEc
Default Setting: 5SEc
CAr: The scanner will hold until the signal disappears,
then will resume after one second.
5SEc: The scanner will hold for five seconds, then re-
sume whether or not the other station is still
transmitting.
042 GEnE ANTIVOX
Function: Adjusts the Anti-VOX Trip Gain which is the
level of negative feedback of receiver audio to the micro-
phone, to prevent receiver audio from activating the trans-
mitter (via the microphone) during VOX operation.
Available Values: 0 ~ 100
Default Setting: 50
043 GEnE FRQ ADJ
Function: Adjusts the reference oscillator.
Available Values: –25 ~ 0 ~ +25
Default Setting: 0
Connect a 50-Ohm dummy load and frequency counter to
the antenna jack; adjust the
[
SUB VFO-B
]
knob so that
the frequency counter reading is same as the VFO fre-
quency while pressing the PTT switch.
ADVICE:
Do not perform this Menu item unless you have a high-
performance frequency counter. Perform this Menu item
after aging the transceiver and frequency counter suffi-
ciently (at least 30 minutes).
MENU MODE
GENERAL GROUP
121


Need help? Post your question in this forum.

Forumrules
1

Forum

yaesu-ft-2000d

Reset search

  • My FT2000D will not Transmit. Have not used it in over a year. I am sure it is something I have done wrong. Whe u puss PTT the signal goes to ZERO. Please Advise! Submitted on 12-9-2020 at 00:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Yaesu FT-2000D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Yaesu FT-2000D in the language / languages: English as an attachment in your email.

The manual is 7,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info