3 PRODUCT DESCRIPTION
3.1 Functional description
3.1.1 Battery management
3.1.2 Event log
3.1.3 Locking time
The reading unit, the communication electronics, the mechanical system and power supply, are integrated within the
knob module.
Dierent transponder carriers can be used as key in the PXPCYMF, for example, ISO card or key fob.
The PXPCYMF has the following system properties:
Up to 16,000 card authorizations can be stored
Up to 65,000 readers per site (doors or rooms, please refer to the Key Manager manual)
Up to 423 events registered in the reader memory
Up to 16 conigurable holidays
255 door groups
1695 blacklist cards
Door pulse time can be programmed from 1 to 15 seconds or toggle
No cabling required
2 Lithium batteries CR2 3V
Battery life cycle: up to 74,500 operations or 10 years, depending on the usage, environment and battery condition
The PXPCYMF knob module comes with a battery management system, which indicates the need for battery
replacement by means of a visible and audio signal, when the battery power reduces (capacity loss) during the inal
1,000 operations of the battery (see chapter7.2.1 Battery Replacement).
Signaling happens in 3 phases:
Phase 1
The battery needs to be changed soon.
If an authorized key is held in front of the knob module, the locking access right is issued. The engagement is
accompanied by red lashing (5x) and 5 short acoustic signals.
Phase 2
The battery needs to be changed.
If an authorized key is held in front of the knob module, the knob module irst lashes green for 5 seconds, then the knob
module engages. The engagement is accompanied by red lashing (5x) and 5 short acoustic signals.
Phase 3
The battery needs to be changed immediately.
If an authorized key is held in front of the knob module, no locking access right is issued, but rather the knob module
goes to the battery change position. In addition, the knob module lashes red 5x and gives 5 short acoustic signals.
The access data, the events log, the settings of the knob module and the time are stored on non-volatile memory and
thus retained even when there is no power supply, for example, when changing the battery or if the battery goes
completely lat.
The time is written to the non-volatile memory once every 30 minutes. If the power supply remains o, then the clock
comes to a standstill after a few seconds and starts running from the last stored value onwards after the power supply
is restored.
After every change of battery, remember to check the time. If required, set the current time.
The last 423 events of the knob module are stored in the event log. Event logging can be enabled or disabled for each
knob module individually, to be able to comply with speciic data privacy guidelines.
The event log can be read via event card or via the PXPRSUSB radio stick.
The locking time deines how long the knob module remains connected after scanning an authorized card. It can be
adjusted from 1 to 15 seconds or toggle (on/o mode). Default value is 3 seconds.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for XPR PXP-CY-MF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of XPR PXP-CY-MF in the language / languages: English as an attachment in your email.

The manual is 1.34 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of XPR PXP-CY-MF

XPR PXP-CY-MF User Manual - German - 18 pages

XPR PXP-CY-MF User Manual - Dutch - 18 pages

XPR PXP-CY-MF User Manual - French - 18 pages

XPR PXP-CY-MF User Manual - Spanish - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info