Emergency Stop, and / or failure of On/o Switches
(NOT RECOMMENDED EXCEPT IN EMERGENCY)
In the case of an emergency that requires the generator to be shut down as
fast as possible:
1.  Turn “OFF” the 240Va.c Outlet Power On/O switches (1 and 2). If the
switches have failed and power is still going to the appliance outlets
quickly move to step 2.
2. Press the engine On/O switch (4) to the “OFF” position as indicated by an
“O” (Fig. AB). The unit should stop running.
If the switches have not shut down the generator, you can quickly remove
/ pull out the plugs of the appliances plugged into the outlets that need
to be shut down.
3.  Where the engine keeps operating, don’t panic, turn the fuel lever / tap
(26) anti clockwise to the “OFF” position (Fig. AA). The generator will run
out of fuel within one minute and then stop.
Do not use the generator again until the generator is serviced by an
authorised service agent and the product is repaired, checked and
the fault corrected.
As always in an emergency protect people that could be in harms way rst.
Carbon build up
Carbon build up can be a problem on generators as the loading on the
engine can vary considerably. Running the generator at low loading for
extended periods can cause carbon build up.
Carbon build up in the engine can be reduced by operating the generator at
approximately 75% of rated load for 25% of the time the generator is used.
i.e, if the generator is used for 4 hours on low load i.e 800W or less, run the
generator for 1 hour at around 75% of rating. This is only required
if the generator has been used for less than 25% of rated load for extended
periods. i.e 2 hrs or more.
NOTE: For best operation and long engine life Use unleaded fuel
without ethanol.
Periodic maintenance
Item Remarks
Pre-operation
check (daily)
Initial 1
months
or 20Hr
Every 3
months
or 50Hr
Every 6
months
or 100Hr
Every 12
months
or 300Hr
Spark plug
Check condition, adjust gap and
clean. Replace if necessary.
Engine oil
Check oil level.
Replace.
Air filter
Clean. Replace if necessary.
Fuel filter
Clean fuel drain filter. Replace if
necessary.
Valve clearance
Check and adjust when engine
is cold.
Fuel line
Check fuel hose for crack or
damage. Replace if necessary.
Exhaust system
Check for leakage. Retighten or
replace gasket if necessary.
Check muffler screen. Clean/
replace if necessary.
Carburettor
Check choke operation.
Starting system
Check On/Off switch ignition
operation.
Decarbonisation
More frequently if necessary.
Fittings/
fasteners
Check all fittings and fasteners
correct if necessary.
Regular maintenance is most important for the best performance and safe operation.
Maintenance Maintenance
Periodic Maintenance
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Workzone INF3800A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Workzone INF3800A in the language / languages: English as an attachment in your email.

The manual is 1,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info