809331
18
Zoom out
Zoom in
Previous page
1/26
Next page
18
All menus relating to temperature sensors
All menus relating to temperature sensors
All the menus associated with the heat pump temperature sensors are shown
below. Note that the user cannot make any changes to the settings in these
menus, only read the current values. Some menus are standard for all models
while others are only available in combination with different accessories. The
sensors give an alarm if the temperature is outside of the permitted range/
values.
Note
All sensors are not included as
standard on the heat pump, some are
available as accessories for different
application areas. See more informa-
tion under respective menus.
The menu shows the return temperature in the heating system, i.e. the water from the
radiators back to the heat pump. The temperature varies with the outdoor temperature.
The menu shows the outdoor temperature. Some deviation compared to the true tempera-
ture may occur due to thermal radiation from the house to the installed outdoor sensor.
The menu shows the set and present temperature in the lower section of the outer jacket
of the hot water cylinder T4 (GT4). The temperature is approximately 5ºC lower than the
temperature of the domestic hot water inside the inner cylinder.
The menu is only applicable together with a fl ow sensor. If an extra curve with mixing
valve is used, for example, for an underfl oor heating system, you can see the temperature
on the fl ow water in the circuit. The temperature varies with the outdoor temperature.
The menu is only applicable together with a room sensor. The menu shows the set point
value and present temperature in the room where the sensor is fi tted.
The menu shows the compressor’s working temperature. The temperature varies
between 70ºC and 125ºC during operations.
The menu shows the fl ow temperature of the central heating water as it leaves the heat
pump. It varies depending on the outdoor temperature and whether the heat pump is in
domestic hot water (DHW) heating mode.
The menu shows the temperature of the water that is fed into the heat pump. It varies
depending on the outdoor temperature and whether the heat pump is in domestic hot
water (DHW) heating mode. The heat pump stops at 57ºC for safety reasons.
The menu shows the temperature of the heat transfer fl uid that is fed into the heat pump
from the collector system. It can vary between -5ºC to +15ºC during a year.
The menu shows the temperature of the heat transfer fl uid that is fed out of the heat
pump to the collector system. Normally, during operations, it is 1.5 - 5.0 degrees lower
than the heat transfer fl uid that is fed into the heat pump.
Basic functions - Customer level 1
Temperature readings
Return radiator GT1
Off 41,3O Now 40,3O
Return
Temperature readings
Out GT2
14,0°
Return
Temperature readings
Hot water GT3
Set 51,0° Now 50,0°
Return
Temperature readings
Shunt, ow GT4
Tgt 40,3° Now 43,0°
Return
Temperature readings
Room GT5
Tgt 20,0° Now 19,5°
Return
Temperature readings
Compressor GT6
90,0°
Return
Temperature readings
Heat tr uid out GT8
45,0°
Return
Temperature readings
Heat tr uid in GT9
40,3°
Return
Temperature readings
Ht tr d(coll)inGT10
0,0°
Return
Temperature readings
Httr d(coll)outGT11
-4,0°
Return
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Worcester Greenstore System at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Worcester Greenstore System in the language / languages: English as an attachment in your email.

The manual is 0.74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info